Download Print this page

YASKAWA iQpump Series Programming Manual page 190

Advertisement

Parameter Name
Parameter
Modbus
Digital Operator
No.
Address
Display
Second Line User
o1-07
0518H
Monitor Selection
2nd Monitor Sel
Third Line User Monitor
o1-08
0519H
Selection
3rd Monitor Sel
Local/Remote Key
o2-01
0505H
Function Selection
Local/Remote Key
OFF Key Function
o2-02
0506H
During Auto Run
Oper OFF Key
User Parameter Default
o2-03
0507H
Value
User Defaults
Drive/kVA Selection
o2-04
0508H
Inverter Model #
Frequency Reference
Setting
o2-05
0509H
Method Selection
Operator M.O.P.
Operation Selection
when Digital Operator is
o2-06
050AH
Disconnected
Oper Detection
Cumulative Operation
o2-07
050BH
Time Setting
Elapsed Time Set
Cumulative Operation
o2-08
050CH
Time Selection
Elapsed Time Run
Cumulative Cooling Fan
o2-10
050EH
Operation Time Setting
Fan ON Time Se t
Fault Trace/Fault History
o2-12
0510H
Clear Function
FLT Trace Ini t
kWh User Monitor (U1-
o2-14
0512H
29) Initialization
kWh MonitorClear
Copy Function Selection
o3-01
0515H
Copy Function Sel
190
Description
Sets the "U1" monitor always displayed on the 4th line of the digital
operator display. Effective only when o1-06 = 1.
Sets the "U1" monitor always displayed on the 5th line of the digital
operator display. Effective only when o1-06 = 1.
Key Selections
Has no function when HOA operator is connected.
0: Disabled
1: Enabled
Determines if the off key on the digital operator will stop the Drive
when Drive is operating from external terminals or serial
communications.
0: Disabled
1: Enabled
Allows storing of current parameter values as a User Initialization
Selection at parameter A1-03.
0: No Change (No user parameter set active).
1: Set Defaults (Saves current parameter settings as user initialization.
A1-03 now allows selecting <1110> for user initialization.
2: Clear All (Clears the currently saved user initialization. A1-03 no
longer allows selecting <1110>.
Sets the kVA of the Drive. Enter the number based on Drive Model #.
Use the
portion of the CIMR-P7
Number.
Determines if the Data/Enter key must be used to input a frequency
reference from the digital operator.
0: Disabled - Data/Enter key must be pressed to enter a frequency
reference.
1: Enabled: -Data/Enter key is not required. The frequency reference is
adjusted by the up and down arrow keys on the digital operator without
having to press the data/enter key.
Determines if the Drive will stop when the digital operator is removed.
0: Disabled - The Drive will not stop when the digital operator is
removed.
1: Enabled - The Drive will fault (OPR) and coast to stop when the
operator is removed.
Sets the initial value of the elapsed operation timer.
Sets how time is accumulated for the elapsed timer (o2-07).
0: Power-On Time (Time accumulates whenever Drive is powered).
1: Running Time (Time accumulates only when Drive is running)
Sets the initial value of the heatsink fan operation time.
Clears the fault memory contained in the U2 and U3 monitors.
0: Disabled (no effect).
1: Enabled - resets U2 and U3 monitors, and returns o2-12 to zero.
Used to reset the kilowatt Hour monitor to zero
0: Disabled (no change).
1: Clear all - Resets U1-29 to zero and returns o2-14 to zero.
COPY Function
This parameter controls the copying of parameters to and from the
digital operator.
0: COPY SELECT (no function)
1: INV -> OP READ - All parameters are copied from the Drive to the
digital operator.
2: OP -> INV WRITE - All parameters are copied from the digital
operator into the Drive.
3: OP<-->INV VERIFY - Parameter settings in the Drive are compared
to those in the digital operator.
Note: When using the copy function, the Drive model number and
software number (U1-14) must match or an error will occur.
Setting
Range
1 to 94
1 to 94
0 or 1
0 or 1
0 to 2
-107 Model
0 to FF
Dependent
0 or 1
0 or 1
0 to 65535
0 or 1
0 to 65535
0 or 1
0 or 1
0 to 3
YASKAWA TM.iQp.02 iQpump Drive Programming Manual
Factory
Menu
Page
Setting
Location
No.
2**
Programming
115
91**
Programming
115
1
Programming
116
1
Programming
116
0
Programming
116
kVA
Programming
117
0
Programming
118
1
Programming
118
0 H
Programming
118
1
Programming
118
0 H
Programming
119
0
Programming
119
0
Programming
119
0
Programming
120

Hide quick links:

Advertisement

loading