YASKAWA iQpump Series Programming Manual page 178

Advertisement

Parameter Name
Parameter
Modbus
Digital Operator
No.
Address
Display
d1-01
Setpoint Reference 1
0280H
Setpoint 1
d1-02
Setpoint Reference 2
0281H
Setpoint 2
d1-03
Setpoint Reference 3
0282H
Setpoint 3
d1-04
Setpoint Reference 4
0283H
Setpoint 4
d1-17
Jog Frequency Reference
0292H
Jog Reference
Denotes that parameter can be changed when the drive is running.
Frequency Reference
d2-01
0289H
Upper Limit
Ref Upper Limit
Frequency Reference
d2-02
028AH
Lower Limit
Ref Lower Limit
Master Speed Reference
d2-03
0293H
Lower Limit
Ref1 Lower Limit
Jump Frequency 1
d3-01
0294H
Jump Freq 1
Jump Frequency 2
d3-02
0295H
Jump Freq 2
Jump Frequency 3
d3-03
0296H
Jump Freq 3
Jump Frequency Width
d3-04
0297H
Jump Bandwidth
Input Voltage Setting
E1-01
0300H
Input Voltage
V/F Pattern Selection
E1-03
0302H
V/F Selection
178
Description
Preset Reference
Digital preset setpoint reference 1. Used when b1-01 = 0 and when in
"hand" mode. Setting units are affected by P1-02.
Digital preset setpoint reference 2. Selected via multi-function input
terminals. Setting units are affected by P1-02.
Digital preset setpoint reference 3. Selected via multi-function input
terminals. Setting units are affected by P1-02.
Digital preset setpoint reference 4. Selected via multi-function input
terminals. Setting units are affected by P1-02.
Jog reference used when a jog is selected via the LCD operator keypad.
This parameter is not available with the HOA operator. Setting units
are affected by o1-03.
Reference Limits
Determines maximum speed command, set as a percentage of
parameter E1-04. If speed command is above this value, actual Drive
speed will be limited to this value. This parameter applies to all speed
command sources.
Determines minimum speed command, set as a percentage of
parameter E1-04. If speed command is below this value, actual Drive
speed will be set to this value. This parameter applies to all speed
command sources.
Determines the minimum speed command, set as a percentage of
parameter E1-04. If speed command is below this value, actual Drive
speed will be set to this value. This parameter only applies
to analog inputs A1 and A2.
Jump Frequencies
These parameters allow programming of up to three prohibited
frequency points for eliminating problems with resonant vibration of
the motor / machine. This feature does not actually eliminate the
selected frequency values, but will accelerate and decelerate the motor
through the prohibited bandwidth.
This parameter determines the width of the deadband around each
selected prohibited frequency point. A setting of "1.0" will result in a
deadband of +/- 1.0 Hz.
V/F Pattern
Set to the nominal voltage of the incoming line.
0: 50 Hz
1: 60 Hz Saturation
2: 50 Hz Saturation
3: 72 Hz
4: 50 Hz VT1
5: 50 Hz VT2
6: 60 Hz VT1
7: 60 Hz VT2
8: 50 Hz HST1
9: 50 Hz HST2
A: 60 Hz HST1
B: 60 Hz HST2
C: 90 Hz
D: 120 Hz
F: Custom V/F
FF: Custom w/o limit
Setting
Factory
Range
Setting
0
0
1 to P1-03
0
Value
0
0
0.0 to
100.0% Programming
110.0
0.0 to
0.0%
110.0
0.0 to
0.0%
110.0
0.0 Hz
0.0 to
0.0 Hz
200.0
0.0 Hz
0.0 to 20.0
1.0 Hz
155 to
255.0
240 V
(240V)
310 to
480 V
510.0
(480V)
0 to FF
F
YASKAWA TM.iQp.02 iQpump Drive Programming Manual
Menu
Page
Location
No.
Programming
36
Programming
36
Programming
36
Programming
36
Programming
37
38
Programming
38
Programming
38
Programming
39
Programming
39
Programming
39
Programming
39
Programming
40
Programming
40