E1-06 Base Frequency
■
Setting Range:
0.0 to 120.0 Hz
Factory Default: 60.0 Hz
E1-07 Mid Output Frequency A
■
Setting Range:
0.0 to 120.0 Hz
Factory Default: 3.0 Hz
E1-08 Mid Output Voltage A
■
Setting Ranges: 0.0 to 255.0 V (240 V Models)
0.0 to 510.0 V (480 V Models)
Factory Defaults: 17.2 V (240 V Models)
34.5 V (480 V Models)
E1-09 Minimum Output Frequency
■
Setting Range:
0.0 to 120.0 Hz
Factory Default: 1.5 Hz
E1-10 Mid Output Voltage
■
Setting Ranges: 0.0 to 255.0 V (240 V Models)
0.0 to 510.0 V (480 V Models)
Factory Defaults: 10.3 V (240 V Models)
20.7 V (480 V Models)
E1-11 Mid Output Frequency B
■
Setting Range:
0.0 to 120.0 Hz
Factory Default: 0.0 Hz
E1-12 Mid Output Voltage B
■
Setting Ranges: 0.0 to 255.0 V (240 V Models)
0.0 to 510.0 V (480 V Models)
Factory Defaults: 0.0 V (240 V Models)
0.0 V (480 V Models)
Top set up custom V/f pattern, program the points shown in the diagram below using parameters E1-04 through E1-13. Be sure that the
following condition is true:
E1-09 ≤ E1-07 ≤ E1-06 ≤ E1-11 ≤ E1-04
E1-13 Base Voltage
■
Setting Ranges: 0.0 to 255.0 V (240 V Models)
0.0 to 510.0 V (480 V Models)
Factory Defaults: 0.0 V (240 V Models)
0.0 V (480 V Models)
To set up a custom V/f pattern, program the points shown in the diagram below using parameters E1-04 through E1-13. Be sure that the
following condition is true:
E1-09 ≤ E1-07 ≤ E1-06 ≤ E1-11 ≤ E1-04
42
YASKAWA TM.iQp.02 iQpump Drive Programming Manual