Fig. 8.16:
Basic connection selected in the Logix Designer
This connection comprises up to 50 bytes for data transmission from the PLC to the MSI 430 module (as-
sembly instance 37). This connection comprises up to 67 bytes for data transmission from the MSI 430
module to the PLC (assembly instance 57). The following table offers an overview of these data bytes.
Tab. 8.2:
Data of the class 1 connection "Logic output (1 to 400) and logic/physical input"
Instance Byte
37
0 to 49
57
0 to 49
50 to 65
66
Other connections supported by the MSI 430 module are listed in the following table. You can find informa-
tion on these assembly instances in the table "Overview of assembly databytes [chapter 8.5.1]".
Leuze electronic
Access
Data type Description
Write,
BYTE[50] Output bytes, configuration
read
via Input data block 1 to 5
in MSI.designer
(More [chapter 8.5.2.1])
Read
BYTE[50] Input bytes, configuration
via Output data block 1 in
MSI.designer
(More [chapter 8.5.3.1])
Read
BYTE[16] Bits of the input terminals
(instance 401 to 528 of at-
tribute 3 class 8, currently
not listed in MSI.designer)
(More [chapter 8.5.3.1])
Read
BYTE
Bit 7: Input state
Bit 6: Output state
(currently not listed in
MSI.designer)
MSI 400
EtherNet/IP gateway
Size
Data range
1 to 50 Bytes 0 to 0xff
1 to 50 Bytes 0 to 0xff
1 to 16 Bytes 0 to 0xff
1 byte
0x00, 0x40,
0x80, 0xc0