Leuze electronic MSI 400 Series Manual page 108

Hide thumbs Also See for MSI 400 Series:
Table of Contents

Advertisement

Octet
9
10 (Bit 0...2)
10 (Bit 3...7)
11
12 to 15
The following table shows the module numbers for the MSI 400 system:
Tab. 9.9:
Module numbers of the MSI 400 system
Module num-
ber
161
162
163
164
165
166
167
168
169
170
171
172
173
174
The following table shows the module-specific diagnostic data (as defined in the GSD) and the correspond-
ing error messages.
Leuze electronic
Content
Comment
0
PROFIBUS slot number of the module. The PROFIBUS gateway sup-
ports five slots, which do not, however, represent physical slots. For this
reason, all messages should be assigned to Slot 0 (the gateway itself).
001 or 010
001 = Incoming error, 010 = Outgoing error
00000...
Alarm sequence number, increased on each state change of octet 10,
11111
bit 0 ... 2 (incoming/outgoing error)
0 to 14
Position of the module that caused the diagnosis message.
0 = controller module
st
1 = 1
I/O module
...
st
13 = 1
nd
14 = 2
(Relay output expansions are not counted)
Variable
4 bytes with module-specific diagnosis data.
See below: Table "PROFIBUS error messages"
Modules
Reserved
MSI-EM-I8 module, MSI-EM-IO84 module, MSI-EM-IO84NP module
PROFIBUS gateway (MSI-FB-PROFIBUS)
CANopen gateway (MSI-FB-CANOPEN)
EtherCAT gateway (MSI-FB-ETHERCAT)
Reserved
Reserved
Reserved
Reserved
Reserved
Controller module 1: 32-bit state
Controller module 2: 32-bit state
Controller module 3: 32-bit state
Unsafe I/O module
Gateway
Gateway
MSI 400
PROFIBUS DP gateway
108