Leuze electronic MSI 400 Series Manual page 125

Hide thumbs Also See for MSI 400 Series:
Table of Contents

Advertisement

Module
Dia-
no.
gnostic
bit
(M5 ... M
2)
02
10
11
12
13
14
15
16
17
18
19
20
21
02
22
23
24
25
26
27
28
29
30
31
Leuze electronic
Emergency
cause
Secure I/O modules
Secure I/O modules
Emergency message
Dual-channel evaluation of input 5-6: Er-
ror detected
Dual-channel evaluation of input 7-8: Er-
ror detected
Reserved
Reserved
Module state input data
Module state output data
Error of the external test signal at input 1.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 2.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 3.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 4.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 5.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 6.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 7.
Check whether there is a short-circuit to
High or a cabling error
Error of the external test signal at input 8.
Check whether there is a short-circuit to
High or a cabling error
Error: Short-circuit after high at output 1
Error: Short-circuit after low at output 1
Error: Short-circuit after high at output 2
Error: Short-circuit after low at output 2
Error: Short-circuit after high at output 3
Error: Short-circuit after low at output 3
Error: Short-circuit after high at output 4
Error: Short-circuit after low at output 4
MSI 400
CANopen gateway
125

Advertisement

Table of Contents
loading