Fig. 5.6:
Drag data bytes into the routing table using drag & drop
NOTICE
i
You can make use of the same data byte several times in the routing table.
"Properties" docking window
In the Properties docking window, the configuration dialog appears for the data byte which you have selec-
ted in the Gateway view.
Depending on the data byte, you can configure individual parameters. You can also allocate tag names
here.
Fig. 5.7:
Configuration dialog in the "Properties" docking window
5.2

Function and basic settings

5.2.1
Routing
The process diagram, transferred to the network from the MSI 400 gateway, comprises the operating data
(e.g. logic results, state of inputs and outputs) and the diagnostic data (e.g. module status, CRCs). This
data have been arranged in 4 data sets.
Tab. 5.2:
Content of data sets 1–4
Data set
Content
1
Process data
2
CRCs
3
State and diagnosis
4
Reserved
Leuze electronic
Configuration of gateways with MSI.designer
Size
50 bytes
32 bytes
60 bytes
60 bytes
MSI 400
Configurable
Yes
No
No
No
36