Technical Data For Supply Circuit; General Technical Data - Leuze electronic MSI 400 Series Manual

Hide thumbs Also See for MSI 400 Series:
Table of Contents

Advertisement

Interface
Connection technology
Slave address (set via
rotary switch)
Slave address (set in
1)
MSI.designer 
Baud rate (kbits/s with
standard line)
125
250
500
800
1000
Line parameters
1)
To set the slave address via software, the hardware address setting must be "0".
12.5

Technical data for supply circuit

These technical data apply to all gateway modules.
Supply circuit
(e.g. via internal safety
bus)
Supply voltage
Power consumption
12.6

General technical data

These technical data apply to all gateway modules.
Connection terminals
Field bus
Climatic conditions
Environmental operating temperature T
Storage temperature
Relative humidity
Climatic conditions (EN 61131-2)
Air pressure during operation
Mechanical strength
Fatigue strength
Shock resistance
• Continuous shock
• Brief shock
Electric safety
Protective type (EN 60529)
Protection class
Electromagnetic compatibility
Leuze electronic
Minimal
5-pin "open style" socket
0
1
see CANopen gateway [chapter 10]
Minimal
Typical
16.8 V DC
24 V DC
See: Interfaces and operation [chapter 9.1]
-25 to +55°C
A
-25 to +70 °C
10 to 95%, non-condensing
860 to 1060 hPa
5 ... 150 Hz (EN 60068‑2‑6)
10 g, 16 ms (EN 60068-2-29)
30 g, 11 ms (EN 60068-2-27)
See MSI 4xx
IP 20
III
EN 61000-6-2/EN 55011 Class A
MSI 400
Typical
Technical data
Maximum
99
127
Maximum line length
500 m
250 m
100 m
40 m
20 m
Maximum
30 V DC
2.4 W
General technical data
172