Leuze electronic MA 258i Operating Instructions Manual
Leuze electronic MA 258i Operating Instructions Manual

Leuze electronic MA 258i Operating Instructions Manual

Fieldbus gateway - ethernet/ip
Table of Contents

Advertisement

Quick Links

MA 258i
Fieldbus Gateway – EtherNet/IP
O r i g in a l op e r a ti n g i n s tr uc t i o ns

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic MA 258i

  • Page 1 MA 258i Fieldbus Gateway – EtherNet/IP O r i g in a l op e r a ti n g i n s tr uc t i o ns...
  • Page 2 © 2017 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone: +49 7021 573-0 Fax: +49 7021 573-199 http://www.leuze.com info@leuze.com Leuze electronic 258i...
  • Page 3: Table Of Contents

    Type overview ............31 Leuze electronic...
  • Page 4 Detailed description of the bits (input byte 1) ........57 258i Leuze electronic...
  • Page 5 14.4 Accessory ready-made cables for voltage supply ......92 Leuze electronic 258i...
  • Page 6 ASCII Table ............112 258i Leuze electronic...
  • Page 7: General Information

    Notice! The Declaration of Conformity for these devices can be requested from the manufacturer. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen, possesses a certified quality assurance system in accordance with ISO 9001. The MA 258i modular interfacing unit is "UL LISTED"...
  • Page 8: Description Of Functions

    CR, LF). The integration of the EDS file in the hardware manager of the PLC is necessary to ensure the correct function of the MA 258i. The corresponding Leuze devices are selected using a rotary code switch on the circuit board of the connector unit.
  • Page 9: Definition Of Terms

    • Online command: These commands refer to the respective, connected ident device and may be differ- ent depending on the device. These commands are not interpreted by the MA 258i, but are instead transmitted transparently (see description of Ident device).
  • Page 10: Safety

    Leuze electronic GmbH + Co. KG is not liable for damages caused by improper use.  Read the technical description before commissioning the device. Knowledge of this technical description is an element of proper use.
  • Page 11: Competent Persons

    BGV A3 (e.g. electrician foreman). In other countries, there are respective regula- tions that must be observed. Disclaimer Leuze electronic GmbH + Co. KG is not liable in the following cases: • The device is not being used properly. • Reasonably foreseeable misuse is not taken into account.
  • Page 12: Fast Commissioning / Operating Principle

    Fast commissioning / operating principle Notice! Below you will find a short description for the initial commissioning of the EtherNet/IP gateway MA 258i. Detailed explanations for the listed points can be found throughout the handbook. Mounting The gateway mounting plate MA...
  • Page 13: Connecting The Leuze Device

    IP 65. Attention! Only then may the supply voltage be applied. Upon startup of the MA 258i, the device selection switch is queried and the gateway automatically sets itself to the Leuze device. Connecting functional earth FE ...
  • Page 14: Ma 258 On Ethernet/Ip

    After all parameters have been set in the planning tool/control, the download to the MA 258i takes place. The set parameters are now stored on the MA 258i. Afterwards, all MA 258i parameters should be stored via upload in the control.
  • Page 15: Manually Setting The Ip Address

    If your system does not include a DHCP server or if the IP addresses of the devices are to be set permanently, proceed as follows:  Have the network administrator specify the data for IP address, net mask and gateway address of the MA 258i. Leuze electronic 258i...
  • Page 16  Connect the serial RS 232 Sub-D interface of the MA 258i to the serial interface of your  Make the respective settings on the configuration page opened in the web browser. 258i Leuze electronic...
  • Page 17: Configure The Participant

    Configure the participant Configuration with the generic EtherNet module In the RSLogix 5000 configuration tool for EtherNet/IP, software version <20.00, a so-called "generic EtherNet module" is created for the MA 258i under the Communication path. Figure 3.4: Generic module Leuze electronic 258i...
  • Page 18 Assembly list The input mask for the Generic module describes: • The name of the participant (can be selected freely; e.g.MA 258i). • The format of the I/O data (data - DINT = 32bit or data - SINT = 8bit).
  • Page 19  After loading, select the device via the device list and enter it into the HW manager via Drag&Drop.  Open the input dialog for setting the address and additional parameters by double-click- ing on the device symbol and make the desired entries here.  Finally, transmit the values to the device via download. Leuze electronic 258i...
  • Page 20: Transfer The Data To The Control (Rslogix 5000 Specific)

    The config assembly must include all parameters that affect the MA 258i. The config assembly is automatically written to the connected participants in cycles that the control manufacturer defines.
  • Page 21  To do this, double-click on the tree node EtherNet.  In the new window, select the desired device from the database and carry out the respec- tive configuration. Figure 3.6: Creating a module  First set the IP address. Leuze electronic 258i...
  • Page 22 Please select the suitable combination for the data length and the connected device. For further information, see chapter 16 "Specifications for Leuze end devices". Figure 3.2: Select combination for the lengths of the input and output data 258i Leuze electronic...
  • Page 23 PT-sequences, or an RFID transponder is to be described. In these cases, larger combinations are usually advisable.  Select the appropriate combination and transmit the settings to the device. Figure 3.7: MA settings in the controller tags Leuze electronic 258i...
  • Page 24: Use Explicit Messaging Services

    MA 258i Attention! If parameters are changed via explicit messaging services while simultaneously activating a configuration assembly, the changed parameters must subsequently be entered in the con- figuration assembly. 258i Leuze electronic...
  • Page 25: Device Description

    For this purpose, device-dependent commands (so-called online commands) are pre- defined via the device selection switch, see chapter 16 "Specifications for Leuze end devices". Leuze electronic 258i...
  • Page 26: Device Construction

    PG cable gland which provide strain relief and protec- tion against contamination. With the help of adapter cables with Sub-D 9 or open cable end, other RS 232 devices can also be connected. 258i Leuze electronic...
  • Page 27: Operating Modes

    If the service switch is on one of the service settings, the MS LED flashes on the front side of the device, see chapter 8.1.2 "LED indicators on the housing". Furthermore, on the control, the SMA service bit of the status bytes signals that the MA is in service mode. Leuze electronic 258i...
  • Page 28: Fieldbus Systems

    The MA 258i features multiple M12 connectors / sockets for the electrical connection of the supply voltage, the interface and the switching inputs and outputs. Additional information on the electrical connection can be found in chapter 7. 258i Leuze electronic...
  • Page 29 In addition to the classic "star topology", a "linear topology" is thus also possible. PC / PLC host interface to other network participants 258i 258i 258i "192.168.0.100" "192.168.0.101" "192.168.0.102" Figure 4.5: EtherNet/IP with linear topology Leuze electronic 258i...
  • Page 30 Addressing of the object instance within the object class. Attribute identifier (attribute) Addressing of the attribute within the object instance. Service code (get, set, reset, start, stop and others...) The maintenance code ultimately describes the type of access to the data, e.g., reading or writing. 258i Leuze electronic...
  • Page 31: Specifications

    IP 65 (with screwed-on M12 and connected Leuze device) Weight 700 g Dimensions (HxWxD) 130 x 90 x 41mm / with plate: 180 x 108 x 41mm Housing Diecast aluminum Connection 2 x M12: BUS IN / BUS OUT EtherNet/IP 1 connector: RS 232 Leuze electronic 258i...
  • Page 32: Dimensioned Drawings

    EN 61000-6-2:2005 (interference rejection for indus- trial sectors) Certifications UL 60950-1, CSA C22.2 No. 60950-1 For UL applications: only for use in "Class 2" circuits acc. to NEC. Dimensioned drawings Figure 5.1: Dimensioned drawing MA 258 258i Leuze electronic...
  • Page 33: Type Overview

    PROFIBUS DP V0 MA 204 50112893 Ethernet TCP/IP MA 208 50112892 PROFINET-IO RT MA 248 50112891 DeviceNet MA 255 50114156 CANopen MA 235 50114154 EtherCAT MA 238 50114155 EtherNet/IP MA 258 50114157 Table 5.1: Type overview MA 2xx Leuze electronic 258i...
  • Page 34: Installation And Mounting

     Save the original packaging for later storage or shipping. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office.  Observe the applicable local regulations when disposing of the packaging materials.
  • Page 35: Mounting

    • using four threaded holes (M6) or • using two M8 screws on the two lateral grooves. Fastening by means of four M6 or two M8 screws Fastening options Figure 6.2: Fastening options Leuze electronic 258i...
  • Page 36: Device Arrangement

     Clean the housing of the MA 258i with a soft cloth after mounting. Remove all packaging remains, e.g. carton fibers or Styrofoam balls. Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 258i Leuze electronic...
  • Page 37: Electrical Connection

    The fieldbus gateways are designed in accordance with safety class III for supply by PELV (protective extra-low voltage with reliable disconnection). Notice! Protection class IP65 is achieved only if the connectors and caps are screwed into place! Leuze electronic 258i...
  • Page 38: Electrical Connection

    Positive supply voltage +18 … +30VDC SWIO_2 SWIO_2 Switching input/switching output 2 Negative supply voltage 0VDC SWIO_1 Switching input/switching output 1 Functional earth SWIO_1 M12 connector Thread Functional earth (housing) (A-coded) Table 7.1: PWR IN pin assignment 258i Leuze electronic...
  • Page 39 In this case, only the switching input and output on PWR IN are active. The function of the switching inputs and outputs is dependent on the connected Leuze device. Detailed information on this topic can be found in the respective operating instruc- tions. Leuze electronic 258i...
  • Page 40: Pwr Out Switching Input/Output

    BUS IN (4-pin socket, D-coded) BUS IN Name Remark Transmit Data + Receive Data + TD+ 1 Transmit Data - Receive Data - Thread Functional earth (housing) M12 socket (D-coded) Table 7.3: EtherNet/IP BUS IN pin assignment 258i Leuze electronic...
  • Page 41 Electrical connection  For the host connection of the MA 258i, the "KB ET - … - SA-RJ45" ready-made cables are preferred, see table 14.4 Bus connection cable for the MA 258i on page 94. EtherNet/IP cable assignment MA 258 HOST / BUS IN...
  • Page 42: Bus Out

    Table 7.4: EtherNet/IP BUS OUT pin assignment  For the host connection of the MA 258i, the "KB ET - … - SSA" ready-made cables are preferred, see table 14.4 Bus connection cable for the MA 258i on page 94.
  • Page 43: Device Interfaces

    9, the 12-pin X30 PCB connection is available as well. By using an additional cable (cf. "Type overview and accessories" on page 91), the system connection can be established on M12 or 9-pin Sub-D, e.g., for hand-held scanners. Leuze electronic 258i...
  • Page 44: Service Interface (Internal)

    To configure the devices connected to the external interface, e.g., BCL 8 (JST plug connec- tor "X30"), a cable specially configured for this purpose is necessary. The service switch must be in the "DEV" or "MA" position (Service Leuze device/MA). 258i Leuze electronic...
  • Page 45: Status Displays And Operational Controls

    LED (Status) Device OFF - no operating voltage or device defect continuous green light Device ok - readiness for operation continuous orange light Device error / firmware available flashing green-orange Device in boot mode - no firmware Leuze electronic 258i...
  • Page 46: Led Indicators On The Housing

    LINK 0/ ACT 0 LED continuous green light LINK 0 - connection exists flashing yellow ACT 0 - data exchange LINK 1/ ACT 1 LED continuous green light LINK 1 - connection exists flashing yellow ACT 1 - data exchange 258i Leuze electronic...
  • Page 47: Internal Interfaces And Operational Controls

    RS 232 service interface Sub-D Jumper for bridging, separating switching input/output PWR IN/OUT 3 JST plug connectors: connection of the Leuze devices MA 258 : without function/not equipped Figure 8.2: Front view: operational controls of the MA 258 Leuze electronic 258i...
  • Page 48 Switch between service Leuze device (DEV), service fieldbus gateway (MA) and operation (RUN). Standard setting = operation. J1, J2 Bridging, separating switching input/output Jumper (interruption of connection between the two PWR M12 connectors of the SWIO 1/ SWIO 2) 258i Leuze electronic...
  • Page 49: Connector X30

    • Operation (RUN) = default setting • Service Leuze device (DEV) and • Service fieldbus gateway (MA) Figure 8.4: DIP switch service - operation For further information on the corresponding options, see chapter 4.4 "Operating modes". Leuze electronic 258i...
  • Page 50: Rotary Switch S4 For Device Selection

    Notice! In switch position "0", a distance of >20ms must be maintained between two telegrams so they can be distinguished from one another. The parameters of the Leuze end devices are described in chapter 16. 258i Leuze electronic...
  • Page 51: Configuration

     Now start one of the following terminal programs: e.g., BCL, RF, BPS Config. Alternatively, you can also use the Windows tool "Hyperterminal".  Start the program.  Select the correct COM port (e.g., COM1) and set the interface as follows: Leuze electronic 258i...
  • Page 52 Enable memory mode for the last frames. The memory mode shows the last RX and TX frames for ASCII and fieldbus. Table 9.1: Available commands Information Version Version information. Firmware date Firmware date. Table 9.2: General firmware information 258i Leuze electronic...
  • Page 53 ASCII configuration EIS input data length Length of the data received (consumed data, default 4 bytes). EIS output data length Length of the data supplied (produced data, default 18 bytes). IP address Displays the set IP address. Leuze electronic 258i...
  • Page 54 Configuration Gateway address Displays the set gateway address. Network mask Displays the set network mask. DHCP DHCP mode (ENABLED/DISABLED). Table 9.6: Communication parameters MA 258 258i Leuze electronic...
  • Page 55: Telegram

    The corresponding control and status bits and their meaning are specified in section 10.2 and section 10.3. Further information on the broadcast control bytes and address bits 0 … 4 can be found in chapter "Modular interfacing unit MA 3x (S4 switch position C)" on page 110. Leuze electronic 258i...
  • Page 56: Description Of The Input Bytes (Status Bytes)

    Meaning 0 … 7 DLC0 … DLC7 Data Length Code (length of the following user data) Notice! T-bit means toggle bit, i.e. this bit changes its state on each event ("0" → "1" or "1" → "0"). 258i Leuze electronic...
  • Page 57: Detailed Description Of The Bits (Input Byte 0)

    This flag bit is 1: Further data in always set to high ("1") by the fieldbus gateway as long as the transmit buffer data is in the buffer. Leuze electronic 258i...
  • Page 58 While the BO bit is set, the RTS sig- 1->0: nal of the serial interface is deactivated. Buffer o.k. The memory size of the gateway for the data of both the PLC and the Leuze end device is 1 kByte. 258i Leuze electronic...
  • Page 59: Detailed Description Of The Bits (Input Byte 1)

    Bit no. Designation Meaning Command mode Command mode Broadcast Broadcast (only relevant with a connected MA 3x) 2 … 6 Address 0 .. 4 Address bits 0 .. 4 (only relevant with a connected MA 3x) New data Leuze electronic 258i...
  • Page 60: Detailed Description Of The Bits (Output Byte 0)

    Bit 7: New data: ND Output data Description Addr. Data Value range Default type New data 0->1; 1->0: This bit is needed if several identical pieces of data are to be On each status sent in sequence. change for new data 258i Leuze electronic...
  • Page 61: Detailed Description Of The Bits (Output Byte 1)

    Toggle bit: changing this bit causes all data which was copied RS 232 to the transmit buffer of the fieldbus gateway via the CTB bit 1->0: Data to to be transmitted to the RS 232 interface or the connected RS 232 Leuze device. Leuze electronic 258i...
  • Page 62: Reset Function / Deleting Memory

    OUT data byte 0/parameter byte 0: AAh OUT data byte 1/parameter byte 1: AAh This sets the memory or status/control bits to 00h. Please observe that the data image may need to be updated by toggling in Collective mode. 258i Leuze electronic...
  • Page 63: Modes

    CTB bit, it goes directly to the RS 232 interface with the set telegram data length. Incomplete (incl. data frame) or faulty telegrams can cause error messages in the connected device! Combination with the Command mode is possible. Data exchange in blocks must be programmed on the PLC. Leuze electronic 258i...
  • Page 64: Reading Slave Data In Collective Mode (Gateway -> Plc)

    If PLC data is provided and transferred without a state change of the CTB bit, it goes directly to the RS 232 interface with the set telegram data length. Incomplete (incl. data frame) or faulty telegrams can cause error messages in the connected device! 258i Leuze electronic...
  • Page 65 Address 3 Address 2 Address 1 Address 0 Broadcast Control byte 0 mode R-ACK Control byte 1 Data byte 1 Data byte 2 Data … Output byte 0 Output byte 1 Output byte 2 Output byte 3 Leuze electronic 258i...
  • Page 66 All desired data in the buf- (control bit 1.0) fer? Send data with the SFB = ! SFB toggle bit (control bit 1.2) Command ok? W-ACK = ! W-ACK (status bit 0.0) (Display!) Figure 11.1: Data transmission scheme with long online commands 258i Leuze electronic...
  • Page 67: Command Mode

    In Command mode, control or output byte 0.0 is to be set for activating the Command mode. Only the corresponding bit (control or output byte 2.1) then needs to be set for activating and deactivating the reading gate. Output byte 0 Output byte 1 Output byte 2 Output byte 3 Leuze electronic 258i...
  • Page 68 Device executes the corresponding function (cf. chap. 16). For function to be reestablished, the ND bit and the selected bit in byte 2 must be toggled, byte 0.0 can stay. Figure 11.2: Execution of command after activation of the Command mode 258i Leuze electronic...
  • Page 69 Figure 11.3: Activating DEV and reading data Notice! Further information on fieldbus telegram structure can be found in chapter 10.1. A specification of all usable commands can be found in chapter "Specifications for Leuze end devices" on page 97. Leuze electronic 258i...
  • Page 70: Commissioning And Configuration

     Finally, close the housing of the MA 258i. Attention! Only then may the supply voltage be applied. Upon startup of the MA 258i, the device selection switch is queried and the gateway auto- matically sets itself to the Leuze device. PWR IN...
  • Page 71: Starting The Device And Setting The Communication Parameters

    Starting the device and setting the communication parameters As a first step, you need to start the device and set the communication parameters of the MA 258i. With the communication parameters, you determine how data is exchanged between the MA and host system, monitor PCs etc.
  • Page 72 The service switch must be in switch position "MA" for the MA 208i to start in configuration mode.  Connect the serial RS 232 Sub-D interface of the MA 258i to the serial interface of your computer.  Make the respective settings on the configuration page opened in the web browser. 258i Leuze electronic...
  • Page 73: Configuration Steps For A Rockwell Control Without Eds Support

    12.3.1 Integrating the hardware into the PLC using the generic EtherNet module In the RSLogix 5000 configuration tool for EtherNet/IP, software version <20.00, a so-called "generic EtherNet module" is created for the MA 258i under the Communication path. Figure 12.4: Generic module Leuze electronic 258i...
  • Page 74 Figure 12.5: Assembly list The input mask for the generic module describes: • The name of the participant (can be selected freely; e.g.MA 258i). • The format of the I/O data (data - DINT = 32bit or data - SINT = 8bit).
  • Page 75: Configure The Config Assembly

    The config assembly must include all parameters that affect the MA 258i. The config assembly is automatically written to the connected participants in cycles that the control manufacturer defines.
  • Page 76 Please find a detailed description of the Leuze-specific assembly in chapter 12.6.2. Byte 00+01: DataMode (collective/transparent mode) Byte 02+03: Serial line mode (rotary / EDS) Byte 04+05: Baud rate (9600Bd) Byte 06+07: Data bits (7/8 data bits) Byte 08+09: Parity (N/E/O) Byte 10+11: Stop bits (1/2) 258i Leuze electronic...
  • Page 77 Commissioning and configuration Figure 12.6: Entering the byte parameters  Transfer the settings made to the device via EtherNet module -> Properties via Reset module. Figure 12.7: Transferring manual MA settings to the device Leuze electronic 258i...
  • Page 78: Configuration Steps For A Rockwell Control With Eds Support

    12.4.1 Integrating the hardware into the PLC and installing the EDS file To integrate the device and to establish a connection between the PLC and the device MA 258i, proceed as follows:  First, load the EDS file for the device via EDS wizard into the PLC database.
  • Page 79 Commissioning and configuration Figure 12.8: Creating a module  First set the IP address. Figure 12.9: Setting the IP address of the MA Attention! The IN/OUT combinations can only be selected from the list! Leuze electronic 258i...
  • Page 80 A longer length is needed, for example, if a BCL bar code scanner is to be configured by means of PT-sequences, or an RFID transponder is to be described. In these cases, larger combinations are usually advisable.  Select the appropriate combination and transmit the settings to the device. 258i Leuze electronic...
  • Page 81 We thus recommend creating the settings using SINT. After all parameters have been set in the planning tool/control, the download to the MA 258i takes place. The set parameters are now stored on the MA 258i. Afterwards, all MA 258i parameters should be stored via upload in the control.
  • Page 82: Eds File - General Info

    Commissioning and configuration Each time a connection is established between the control and the MA 258i, these param- eters are now transmitted again to the MA 258i. Note that this function must be supported by the control. The EtherNet baud rate is defined for the entire network in the planning tool/control. The...
  • Page 83: Eds File - Detailed Description

    ODVA, the MA 258i is assigned number 12 = 0C 12.6.1.3 Product Code The product code is an ID assigned by Leuze electronic that has no further impact on other objects. 12.6.1.4 Revision Version number of the identity object. Leuze electronic...
  • Page 84: Class 4 Assembly Object

    20.00 and up only. For older versions without support for the EDS integration, the respective device can only be created via the "generic module" in the PLC. When doing so, the values of the input and output data lengths must be manually entered according to the following table. 258i Leuze electronic...
  • Page 85 Data content with max. 62 /2 bytes Data, 20 In/8 Out Data content with max. 18 /6 bytes Data, 64 In/8 Out Data content with max. 62 /6 bytes Table 12.1: Overview of all possible combinations of input and output data lengths Leuze electronic 258i...
  • Page 86 0000 = Transparent mode (default) 0100 = Collective mode Byte 0+1: 0000 , LowByte first Serial line mode Parameter value: 0000 = Use rotary switch (default) 0100 = Use EDS settings Byte 2+3: 0000 , LowByte first 258i Leuze electronic...
  • Page 87 0100 = None (default) 0200 = Even 0300 = Odd Byte 8+9: 0100 , LowByte first RS 232 Stop Bits Parameter value: 0100 = 1 bit (default) 0200 = 2 bit Byte 10+11: 0100 , LowByte first Leuze electronic 258i...
  • Page 88: Setting The Read Parameters On The Leuze Device

    The Leuze device is now connected to the fieldbus. Activation of the Leuze device can now occur via the switching input on the MA 258i, via the process data word Out bit 1 (bit 0.2) or by transmitting a "+" command to the Leuze device (see chapter 16 "Specifications for Leuze end devices").
  • Page 89: Specific Feature For The Use Of Hand-Held Scanners (Bar Code And 2D Devices, Combi Devices With Rfid)

    PIN 9). The corresponding cable is to be selected for the respective hand-held scanner and ordered separately. The 9-pin Sub-D cable (KB JST-HS-300, part no. 50113397) is connected to this cable, which is connected to the MA 258i. This cable must also be ordered separately.
  • Page 90: Specific Features In The Operation Of An Rfm/Rfi

    Each of these (hexadecimal) characters is, in turn, to be handled as an individual ASCII character and converted to hexadecimal format for transmission via the fieldbus. Example: Control byte 0 Control byte 1 Data CHAR Plain text 258i Leuze electronic...
  • Page 91: Diagnostics And Troubleshooting

    NS LED on the housing (see figure 8.1 on page 43) Red continuous light Network error. Check wiring. LINK /ACT LEDs on the housing (see figure 8.1 on page 43) No connection. Check wiring/IP address. Table 13.1: General causes of errors Leuze electronic 258i...
  • Page 92: Interface Errors

    Customer data (please complete) Device type: Company: Contact partner / department: Phone (direct): Fax: Street / No: ZIP code/City: Country: Leuze Service fax number: +49 7021 573 - 199 258i Leuze electronic...
  • Page 93: Type Overview And Accessories

    KD 095-5A M12 socket for voltage supply 50020501 KS 095-4A M12 connector for SW IN/OUT 50040155 D-ET1 RJ45 connector for user-configuration 50108991 S-M12A-ET Connector, axial, M12 connector, D-coded, terminals 50112155 Table 14.2: Connectors for the MA 258 Leuze electronic 258i...
  • Page 94: Accessory Ready-Made Cables For Voltage Supply

    SWIO_1 black gray SWIO_1 M12 connector Thread bare (A-coded) 14.4.2 Specifications of the cables for voltage supply Operating temperature range in rest state: -30°C … +70°C in motion: 5°C … +70°C Material sheathing: Bending radius > 50mm 258i Leuze electronic...
  • Page 95: Order Codes Of The Cables For Voltage Supply

    M12 EtherNet connection cable (4-pin connector, D-coded, on both sides) Name Core color Ethernet yellow white orange blue SH (thread) bare M12 connector (D-coded) Core color Conductor class: VDE 0295, EN 60228, IEC 60228 (class 5) Figure 14.1: Cable structure of Industrial EtherNet connection cable Leuze electronic 258i...
  • Page 96: Technical Data Of The M12 Ethernet Connection Cables Kb Et

    KB ET - 2000 - SSA Cable length 2m 50106899 KB ET - 5000 - SSA Cable length 5m 50106900 KB ET - 10000 - SSA Cable length 10m 50106901 Table 14.4: Bus connection cable for the MA 258 258i Leuze electronic...
  • Page 97: Accessory Ready-Made Cables For Connecting Leuze Ident Devices

    K-D M12A-5P-5000/10000 connection cable (5-pin with injection molded connector), open cable end Core color brown white blue black gray KB JST 3000 (RS 232 connection cable, JST pin strip 10-pin, open cable end) Signal Core color JST 10-pin TxD 232 RxD 232 brown orange shield Leuze electronic 258i...
  • Page 98: Maintenance

     Contact your Leuze distributor or service organization should repairs be required. The addresses can be found on the inside of the cover and on the back. Notice! When sending devices to Leuze electronic for repair, please provide an accurate description of the error. 15.3...
  • Page 99: Specifications For Leuze End Devices

    "Configuration assembly"/ EDS file. In the factory setting, the S4 switch position is 0. Resetting the settings to these is possible in S4 switch position F. The procedure for doing this is described in chapter 16.13. Leuze electronic 258i...
  • Page 100 First, the following settings are to be performed on the device using KONTURFlex-Soft: • Either "Autosend (fast)" or "Autosend with data in Modbus format" • Repeat time "31.5ms" • Autosend baud rate "38.4KB" • 2 stop bits, no parity 258i Leuze electronic...
  • Page 101: Bar Code Reader Bcl 8 (S4 Switch Position 1)

    With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. Leuze electronic 258i...
  • Page 102: Bar Code Reader Bcl 22 (S4 Switch Position 2)

    With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. 258i Leuze electronic...
  • Page 103: Bar Code Reader Bcl 300I, Bcl 500I, Bcl 600I (S4 Switch Position 4)

    With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. Leuze electronic 258i...
  • Page 104: Bar Code Reader Bcl 90, Bcl 900I (S4 Switch Position 5)

    With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. 258i Leuze electronic...
  • Page 105: Lsis 122, Lsis 222 (S4 Switch Position 6)

    2D code that is to be read. With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. Leuze electronic 258i...
  • Page 106: Lsis 4X2I, Dcr 202I (S4 Switch Position 7)

    2D code that is to be read. With an 18-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. 258i Leuze electronic...
  • Page 107: Hand-Held Scanner (S4 Switch Position 8)

    With an 12-digit bar code (+ 2 bytes of status bytes), for example, it is advisable to use the "20 bytes In/4 bytes Out" combination. Leuze electronic 258i...
  • Page 108: Rfi, Rfm, Rfu Rfid Readers (S4 Switch Position 9)

    For the reading of a 16-digit serial number (+ 2 bytes of status bytes), for example, it is advisable to use the "64 bytes In/8 bytes Out" combination. The RFID devices expect the telegrams / data in HEX format. 258i Leuze electronic...
  • Page 109: Bps 8 Bar Code Positioning System (S4 Switch Position A)

    In this switch position, the MA automatically sends a position request to the BPS 8 every 10ms until another command comes via the control. Automatic request only restarts when a new position request is sent by the PLC or when the MA is restarted. Leuze electronic 258i...
  • Page 110: Bps 300I Bar Code Positioning System, Odsl Xx Optical Distance Sensors With Rs 232 Interface (S4 Switch Position B)

    Transmit single position and speed value C0F838 Cyclically transmit position and speed values C0F939 Transmit marker information C0FA3A Not used / reserved Transmit diagnostic information C0FC3C Activate standby C0FD3D Recommended settings • Produced/Consumed data settings: "20 bytes In/8 bytes Out" 258i Leuze electronic...
  • Page 111 The ODSL 9/96B is to be operated in the "Precision" measure mode. The mode is set through the display menu via Application -> Measure mode -> Precision. You can find more details on this in the technical description. Leuze electronic 258i...
  • Page 112: Modular Interfacing Unit Ma 3X (S4 Switch Position C)

    With an 18-digit bar code (+ 2 bytes of status bytes + 2 bytes of slave address), for example, it is advisable to use the "64 bytes In/4 bytes Out" combination. Notice! In this switch position, the address of the multiNet slave is also transmitted in the first two bytes of the data range! 258i Leuze electronic...
  • Page 113: Resetting The Parameters (S4 Switch Position F)

     Set device switch S4 to F in a voltage free state.  Switch the voltage on and wait until it is ready for operation.  If necessary, switch the voltage off to prepare for commissioning.  Set service switch S10 to the "RUN" position. Leuze electronic 258i...
  • Page 114: Appendix

    Record separator UNIT SEPARATOR Unit separator SPACE Space EXCLAMATION POINT Exclamation point " QUOTATION MARK Quotation mark NUMBER SIGN Number sign DOLLAR SIGN Dollar sign PERCENT SIGN Percent sign & AMPERSAND Ampersand APOSTROPHE Apostrophe OPENING PARENTHESIS Opening parenthesis 258i Leuze electronic...
  • Page 115 Plus sign COMMA Comma HYPHEN (MINUS) Hyphen (minus) PERIOD (DECIMAL) Period (decimal) SLANT Slant COLON Colon SEMICOLON Semicolon < LESS THAN Less than EQUALS Equals > GREATER THAN Greater than QUESTION MARK Question mark COMMERCIAL AT Commercial AT Leuze electronic 258i...
  • Page 116 OPENING BRACKET Opening bracket REVERSE SLANT Reverse slant CLOSING BRACKET Closing bracket CIRCUMFLEX Circumflex UNDERSCORE Underscore ‘ GRAVE ACCENT Grave accent OPENING BRACE Opening brace VERTICAL LINE Vertical line CLOSING BRACE Closing brace TILDE Tilde DELETE (RUBOUT) Delete 258i Leuze electronic...
  • Page 117 Fast commissioning ....10 Fieldbus systems ..... 26 Leuze electronic 258i...
  • Page 118 Indicators ......29 Mechanical data ....29 258i Leuze electronic...

Table of Contents