If your MSI 400 system contains two gateways, it is possible to forward information which the first gateway
receives from a network (e.g. from an EhterCAT PLC) via the second gateway to a second network (e.g. to
a PROFIBUS master) and vice versa.
Expert setting: Allocating bytes to other addresses
MSI.designer has pre-assigned the addresses according to a default. You can manually change this ad-
dress allocation by moving any number of bytes.
In our example, we have shifted byte 1 to byte 23 in output data block 0.
Step 1: Check target address
Ä Ensure that the desired address (byte 23 in our example) has not been allocated.
Ä When the target address is assigned here, delete the bytes placed there.
To do this, click on the byte in the work area and click on the Delete symbol in the command bar.
Step 2: Delete byte from original address
Ä Delete the byte you wish to reallocated (byte 0 in our example).
To do this, click on the byte in the work area and click on the Delete symbol in the command bar.
Step 3: Place byte on new target address
Ä Open the Gateway docking window and select the desired bytes under the associated module.
Ä Use the mouse button to drag the Byte into the work area on byte 23.
Leuze electronic
MSI 400
EtherCAT Gateway