Star Line Thermal/Dot Printer Specifications page 129

Line thermal/dot printer star line mode command specifications
Table of Contents

Advertisement

ESC FS p n m
[Name]
Print logo
[Code]
ASCII
Hexadecimal
Decimal
[Defined Area]
Thermal
Slip
Validation
[Initial Value]
Thermal
Slip
Validation
[Function]
Prints the logo of registration number n registered using the logo registration command ESC FS q
according to the print mode m.
n: Logo Specification
n
1 to 255
Specified logo number
m: Printing Mode
m
0, 48
Normal mode
1, 49
Double wide mode
2, 50
Double high mode
3, 51
Double high/wide mode
If the parameter is within the defined region, execute this command after printing the unprinted data
in the line buffer.
(Unprinted data is printed regardless of whether the specified logo was registered by n.) )
It is not possible to print with other data in one line (characters, bit images, bar codes).
Form feed obeys the vertical print size of the logo.
Print modes, excluding upside-down printing (enhanced, double, underline, character size, black/
white inverted, and 90˚ right rotation) are unaffected.
If the logo horizontal print size exceeds the horizontal print region, the portion exceeding the area is
not printed.
Logos are printed according to the following command settings.
• Left margin (ESC I n)
• Right margin (ESC Q n)
• Position alignment (ESC GS a n)
• Absolute position movement (ESC GS A n1 n2)
• Relative position movement (ESC GS R n1 n2)
• Horizontal tab (HT)
• Upside-down printing (SI)
<When using the 2 color print mode>
When the logo register number n is odd:
When the logo register number n is even:
STAR Line Mode Command Specifications
ESC
FS
p
n
m
1B
1C
70
n
m
27
28
112
n
m
:
1 ≤ n ≤ 255
0 ≤ m ≤ 3, 48 ≤ m ≤ 51, ("0" ≤ m ≤ "3")
:
1 ≤ n ≤ 255
0 ≤ m ≤ 3, 48 ≤ m ≤ 51, ("0" ≤ m ≤ "3")
:
1 ≤ n ≤ 255
0 ≤ m ≤ 3, 48 ≤ m ≤ 51, ("0" ≤ m ≤ "3")
:
-
:
-
:
-
Logo print mode
Register number n is printed in black; register number n + 1 is printed in red and overlapped.
The command is ignored when the capacity of the register number n and the capacity of the
register number n + 1 are different.
The command is ignored when the register number n = 255 is specified.
Register number n is printed in black; register number n - 1 is printed in red and overlapped.
The command is ignored when the capacity of the register number n and the capacity of the
register number n - 1 are different.
The command is ignored when the register number n = 255 is specified.
Function