Star Line Thermal/Dot Printer Specifications page 127

Line thermal/dot printer star line mode command specifications
Table of Contents

Advertisement

ESC FS q n [ x 11 x 1 2 y 11 y 1 2 d 1 ... d k ] 1 ... [ x n 1 x n 2 y n 1 y n 2 d 1 ... d k ] n
[Name]
Register logo
[Code]
ASCII
Hexadecimal
Decimal
[Defined Area]
Thermal
Slip
Validation
[Initial Value]
Thermal
Slip
Validation
[Function]
Parameter details
• n:
• xn1, xn2:
• yn1, yn2:
• d:
• k:
This command should be specified at the top of the line.
When the first parameter is determined to be free of error, the printer starts processing this com-
mand.
When logo register processing starts, all previously defined data is deleted.(It is not possible to re-
register a portion of a plurality of defined logo data.)
Logo registration numbers are defined in rising order from 1.
If the defined area specified by the parameter is not empty, or if there is an error in the parameter
specification, register processing is aborted.(The pre-registered and complete data is effective.)
The printer should be reset if logo registration is completed or register processing is aborted.
If an error occurs while performing register processing (the time from when the first parameter is OK
until the printer initialization is completed after registering a logo), error processing, mechanical op-
eration and status processing cannot be performed. Also, data must not be sent from the host during
that time.
This command is executed only for logo registration and does not accompany the printing operation.
Logos are printed using the ESC FS p (print NV logo) command.
• The NV memory capacity is 4 Mbits (512 Kbytes = 524,288 bytes).
However, 4 Kbytes (4,096 bytes) are kept as parameter information separate to the data so the data
region memory capacity is 520,192 Bytes.
Ex.:
ter 520,192/6144 = 84.
<When registering logos for 2 color printing>
Registration is possible regardless of the 2 color printing mode being specified or cancelled. Register
logos with the same capacity as the logo register number k (odd number) and k + 1 (even number).
If the capacity differs or the logo register number is 255, this command is ignored by the logo print
command in the 2 color print mode.
STAR Line Mode Command Specifications
ESC
FS
q
n
[x11
1B
1C
71
n
[x11
27
28
113
n
[x11
:
1 ≤ n ≤ 255
0 ≤ xn1 ≤ 255, 0 ≤ xn2 ≤ 3 1 ≤ (xn1 + xn2 x 256) ≤ 1023
0 ≤ yn1 ≤ 255, 0 ≤ yn2 ≤ 1 1 ≤ (yn1 + yn2 x 256) ≤ 288
0 ≤ d ≤ 255
k = {(xn1 + xn2 x 256) x (yn1 + yn2 x 256) x 8}
:
1 ≤ n ≤ 255
0 ≤ xn1 ≤ 255, 0 ≤ xn2 ≤ 3 1 ≤ (xn1 + xn2 x 256) ≤ 1023
0 ≤ yn1 ≤ 255, 0 ≤ yn2 ≤ 1 1 ≤ (yn1 + yn2 x 256) ≤ 288
0 ≤ d ≤ 255
k = {(xn1 + xn2 x 256) x (yn1 + yn2 x 256) x 8}
:
1 ≤ n ≤ 255
0 ≤ xn1 ≤ 255, 0 ≤ xn2 ≤ 3 1 ≤ (xn1 + xn2 x 256) ≤ 1023
0 ≤ yn1 ≤ 255, 0 ≤ yn2 ≤ 1 1 ≤ (yn1 + yn2 x 256) ≤ 288
0 ≤ d ≤ 255
k = {(xn1 + xn2 x 256) x (yn1 + yn2 x 256) x 8}
:
-
:
-
:
-
Specifies registered logo count
Horizontal size of registered logo {(xn1 + xn2 x 256) x 8} dots
Vertical size of registered logo {(yn1 + yn2 x 256) x 8} dots
Registered logo data
Logo data count
When the registered data size per each one is 6 Kbytes (6,144 bytes), it is possible to regis-
x12
y11
y12
d1
..
x12
y11
y12
d1
..
x12
y11
y12
d1
..
3-115
dk]1
..
[xn1
xn2
yn1
dk]1
..
[xn1
xn2
yn1
dk]1
..
[xn1
xn2
yn1
Rev. 0.00
yn2
d1
..
dk]n
yn2
d1
..
dk]n
yn2
d1
..
dk]n