NEC Express5800 Series Maintenance Manual page 205

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
BMC Message on Lower LCD Line
Sensor Failure Detected.
SMI timeout
Soft Power Control Failure
IPMI Watchdog timer timeout
IPMI Watchdog timer timeout (Power
off)
Mezzanine Card1 Power Fault
Mezzanine Card2 Power Fault
Drive X Fault (X: number)
E-Keying inconsistency Error (Not
Power ON)
Location Error (Not Power ON)
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash Erase
Error
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
Node Manager can't communicate
BMC
Node Manager Manufacturing Error
Node Manager Persistent Storage
Integrity Error
Cause
Abnormality in a sensor was
detected.
A timeout occurred while
servicing system management
interrupts.
Power-on has been suppressed.
A watchdog timer timeout
occurred.
An error occurred on power
supply circuit of mezzanine card
installed in Type 1 mezzanine
card slot of CPU blade.
An error occurred on power
supply circuit of mezzanine card
installed in Type 2 mezzanine
card slot of CPU blade.
A failure was detected on disk
drive installed in CPU blade.
X: Disk drive number (0-origin)
In the Blade Enclosure,
combination of installation
locations of CPU blade,
mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal
was detected and the CPU blade
failed to power on.
In the Blade Enclosure, the
installation location of CPU blade
is incorrect, or the installation
locations of the fan unit and CPU
blade are incorrect. Thus, the
CPU blade failed to power on.
Abnormality in Node Manager
occurred.
Express5800/B120f Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Check installation status of the failed
mezzanine card. If this does not
resolve the problem, contact your sales
representative.
Contact your sales representative.
Refer to the User's Guide of the Blade
Enclosure to make sure that the CPU
blade and switch module are installed
in correct locations. If this does not
resolve the problem, contact your sales
representative.
Refer to the User's Guide of the Blade
Enclosure to make sure that the CPU
blade is installed in correct locations.
Check if the fan units and CPU blades
are installed in correct locations. If this
does not resolve the problem, contact
your sales representative.
Turn off the power, wait for at least 30
seconds, and restart the server. If this
does not resolve the problem, contact
your sales representative.
205

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f

Table of Contents