NEC Express5800 Series Maintenance Manual page 195

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
(1)
Error messages
Error Message
8000
System variable is corrupted. BIOS setup information is invalid.
8001
Real time clock error
8002
Check date and time settings
8003
System battery is dead -
Replace and run SETUP
8005
Previous boot incomplete -
Default configuration used
8006
System configuration data
cleared by Jumper.
8007
SETUP Menu Password cleared by
Jumper.
8020
BIOS update error.
8021
Recovery jumper is set, but
recovery images is not found.
8800
DXE_NB_ERROR
8801
DXE_NO_CON_IN
8802
DXE_NO_CON_OUT
8803
PEI_DXE_CORE_NOT_FOUND
8804
PEI_DXEIPL_NOT_FOUND
8805
DXE_ARCH_PROTOCOL_NOT_AVAILA
BLE
8806
PEI_RESET_NOT_AVAILABLE
8807
DXE_RESET_NOT_AVAILABLE
8808
DXE_FLASH_UPDATE_FAILED
8830
PEI_RECOVERY_NO_CAPSULE
8831
PEI_RECOVERY_PPI_NOT_FOUND
8832
PEI_RECOVERY_FAILED
9000
Unsupported CPU detected
9001
Unsupported CPU detected on
CPU #1
9002
Unsupported CPU detected on
CPU #2
Cause
Real-time clock error occurred.
An incorrect time setting in real-time
clock was detected.
The battery for storing system
settings is dead.
The previous POST processing did
not finish.
The settings of SETUP were cleared
using the jumper.
The password of SETUP was
cleared using the jumper.
BIOS update failed.
Recovery jumper is set, but
recovery images are not found.
An error occurred during chip set
initialization.
An error occurred during console
initialization.
The BIOS flash memory is corrupt.
The system was not reset correctly
The BIOS flash memory was not
written to correctly.
The BIOS flash memory was not
recovered correctly.
An unsupported CPU was detected.
Express5800/B120f Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Start BIOS Setup Utility (SETUP), and
then execute Load Setup Defaults and
specify the necessary settings. If the same
error is detected repeatedly, contact your
sales representative.
Start SETUP, and then specify the correct
date and time. If the same error is
detected repeateldy, contact your sales
representative.
Contact your sales representative to
request a battery replacement.
After the replacement, run SETUP, and
then specify the correct settings.
Start SETUP, and then execute Load
Setup Defaults and specify the
necessary settings.
Follow the steps described in Chapter 1
(7. Resetting and Clearing the Server).
Start SETUP, and then setup each item
again.
If the same error continues to occur,
contact your sales representative.
This error message also appears when
lithium battery is replaced.
Follow the steps described in Chapter 1
(7. Resetting and Clearing the Server).
Start SETUP, and then setup each item
again.
If the same error continues to occur,
contact your sales representative.
Try BIOS update again.
If the same error is detected repeatedly,
contact your sales representative.
Contact your sales representative.