Releasing The Cable Retention Bracket; Replacing A 3.5 Inch Drive Assembly Or Blank Carrier - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

5. Push the power supply unit back into the enclosure until the handle starts to
6. Finish inserting the power supply unit into the enclosure by closing the handle
7. Reattach the power cable and cable retention bracket.
8. Turn on the power switch to the power supply unit.
What to do next
If required, return the battery. Follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.

Releasing the cable retention bracket

Release the cable retention bracket when removing the power cords from the
power supply unit.
Releasing the cable retention bracket
This topic provides instructions for releasing the cable retention bracket when
removing the power cords from the power supply unit.
About this task
Be careful when you are replacing the hardware components that are located in the
back of the system that you do not inadvertently disturb or remove any cables that
you are not instructed to remove.
Each cable retention bracket comes attached to the back of the power supply unit
by the power cord plug-in.
To release a cable retention bracket, perform these steps:
Procedure
1. Unlock the cable retention bracket that is around the end of the power cord.
2. Pull the lever next to the black plastic loop slightly towards the center of the
3. Continue to pull the lever towards you as you slide the cable retention bracket

Replacing a 3.5 inch drive assembly or blank carrier

Remove and replace a 3.5 inch drive assembly or a blank carrier.
Replacing a Storwize V7000 Gen2 3.5-inch drive assembly
You can replace a faulty 3.5-inch drive assembly with a new one received from
CRU / FRU stock.
About this task
The status of the drive must be such that it is not a spare or a member. The status
is shown in Pools > Internal Storage in the management GUI.
320
Storwize V7000 Unified: Problem Determination Guide 2073-720
d. Place the replacement battery in the opening on top of the power supply in
its proper orientation.
e. Press the battery to seat the connector.
f. Place the handle in its downward location
move.
until the locking catch clicks into place.
canister.
away from the end of the cable.