Problem: Unable To Log On To The Management Gui; Problem: Cannot Initialize Or Create A Clustered System - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

v If the system IP address settings are incorrect for your environment, take these

Problem: Unable to log on to the management GUI

If you can see the management GUI login screen but cannot log on, you have
several options for correcting the problem.
Log on using your user name and password. Complete the suggested actions when
you encounter a specific situation.
v If you are not logging on as superuser, contact your system administrator to
v If the user name that you are using is authenticated through a remote
v If you do not know the password for superuser, go to "Procedure: Resetting

Problem: Cannot initialize or create a clustered system

Use this information if your attempt to create a clustered system has failed. This
information varies depending on the generation of your control enclosure model.
Storwize V7000 Unified Gen1 refers to the enclosure models in the following table:
240
Storwize V7000 Unified: Problem Determination Guide 2073-720
configuration is compatible with the gateway and subnet or prefix settings.
Ensure that you have not used the Ethernet address of another device as the
management address. If necessary, modify your network settings to establish a
connection.
steps:
1. Determine the service address of the configuration node canister. You can
determine this if you can access the service assistant on any node canister,
alternatively use the summary data returned, when a USB flash drive is
plugged into a node canister.
2. You can temporarily run the management GUI on the service address of the
configuration node. Point your browser to service address/gui. For example, if
the service address of the configuration node is 11.22.33.44, point your
browser to 11.22.33.44/gui.
3. Use the options in the Settings > Network panel to change the management
IP settings.
4. As an alternative to using the management GUI, you can use the chsystemip
CLI command to correct the system IP address settings by using ssh to the
service IP of the configuration node.
verify your user name and reset your account password.
authentication server, verify that the server is available. If the authentication
server is unavailable, you can log on as user name superuser. This user is
always authenticated locally.
superuser password" on page 250.
Table 72. Storwize V7000 Unified Gen1 model numbers
Machine
type/model
Description
2076-112
Storwize V7000 Unified control enclosure for up to 12 3.5-inch (8.89
cm) drives
2076-124
Storwize V7000 Unified control enclosure for up to 24 2.5-inch (6.35
cm) drives
2076-312
Storwize V7000 Unified control enclosure for 3.5-inch drives (with two
10 Gbps iSCSI/FCoE Ethernet ports)
2076-324
Storwize V7000 Unified control enclosure for 2.5-inch drives (with two
10 Gbps iSCSI/FCoE Ethernet ports)

Advertisement

Table of Contents
loading

Table of Contents