418
Storwize V7000 Unified: Problem Determination Guide 2073-720
Table 119. Upgrade error codes from using the applysoftware command and recommended
actions (continued)
Error Code
EFSSG4155
EFSSG4155I
EFSSG4156
EFSSG4156A
EFSSG4157
EFSSG4157I
EFSSG4158
EFSSG4158I
EFSSG4159
The applysoftware
command explanation
Unable to mount USB flash
drive.
The applysoftware command
returned upgrade is already
running.
The specified International
Organization for
Standardization (ISO) does
not exist.
The applysoftware command
returned the specified ISO
does not exist.
The specific upgrade
International Organization
for Standardization (ISO)
content is not valid.
The applysoftware command
returned the specific upgrade
ISO invalid content.
The specific upgrade cannot
be installed over the current
version.
The applysoftware command
returned the specific upgrade
cannot be installed over the
current version.
The system is in an
unhealthy state and the
upgrade cannot start.
Action
Back up to a USB flash drive.
Enter #
backupmanagementnode
--unmount /media/usb.
Remove the USB flash drive
and insert again. If the error
persists, remove the USB
flash drive and reboot. When
the system is running, insert
the USB flash drive again.
Verify that the file actually
exists where specified. Also
verify that the command is
passing the correct location
parameters.
The package might be
corrupt. If this problem
persists, download a new
package and try again.
Check the upgrade
documentation and verify
that the level you are coming
from is compatible with the
level you are going to. If the
upgrade level is not
compatible, download the
correct level and try again. If
the upgrade level is
compatible and the error
persists, call the IBM Support
Center.
See Chapter 3, "Getting
started troubleshooting," on
page 47. Determine if the
system has issues.