Storwize V7000 Unified Gen2 Model Numbers - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

Table 74. Storwize V7000 Unified Gen1 model numbers (continued)
Machine
type/model
Description
2076-212
Storwize V7000 Unified expansion enclosure for 3.5-inch drives
2076-224
Storwize V7000 Unified expansion enclosure for 2.5-inch drives
Storwize V7000 Unified Gen2 refers to the newer generation of enclosures in the
following table:
Table 75. Storwize V7000 Unified Gen2 model numbers
Machine
type/model
Description
2076-524
Storwize V7000 Unified control enclosure, with up to 24 2.5-inch (6.35
cm) drives
2076-12F
Storwize V7000 Unified expansion enclosure for up to 12 3.5-inch (8.89
cm) drives
2076-24F
Storwize V7000 Unified expansion enclosure for 2.5-inch drives
Problem: Storwize V7000 Gen2 node canister service IP address
unknown
You can use several methods to determine the service address of a node canister.
A default service address is initially assigned to each node canister, as shown in
Table 76 on page 244. Try using these addresses if the node has not been
reconfigured, and the addresses are valid on your network.
If you are able to access the management GUI, the service IP addresses of the node
canisters are shown by selecting a node and port at Settings > Network > Service
IP Addresses.
If you are unable to access the management GUI but you know the management
IP address of the system, you can use the address to log in to the service assistant
that is running on the configuration node:
1. Point your browser at the /service directory of the management IP address of
the system. If your management IP address is 11.22.33.44, point your web
browser to 11.22.33.44/service.
2. Log in to the service assistant.
3. The service assistant home page lists the node canister that can communicate
with the node.
4. If the service address of the node canister that you are looking for is listed in
the Change Node window, make the node the current node. Its service address
is listed under the Access tab of the node details.
If you know the service IP address of any node canister in the system, you can log
in to the service assistant of that node. Follow the previous instructions for using
the service assistant, but at step 1, point your browser at the /service directory of
the service IP address you know. If you know that a service IP address is
11.22.33.56, point your web browser to 11.22.33.56/service
Chapter 5. Control enclosure
243

Advertisement

Table of Contents
loading

Table of Contents