Storwize V7000 Unified Gen2 refers to the newer generation of enclosures in the
following table:
Problem: Unable to connect to the Storwize V7000 Gen2
management GUI
If you are unable to connect to the management GUI from your web browser and
received a Page not found or similar error, this information might help you resolve
the issue.
Consider the following possibilities if you are unable to connect to the Storwize
V7000 Gen2 management GUI:
v You cannot connect if the system is not operational with at least one node
v Ensure that you are using the correct system IP address. If you can access the
v Ensure that all node canisters have an Ethernet cable that is connected to port 1
238
Storwize V7000 Unified: Problem Determination Guide 2073-720
Table 70. Storwize V7000 Unified Gen1 model numbers
Machine
type/model
Description
2076-112
Storwize V7000 Unified control enclosure for up to 12 3.5-inch (8.89
cm) drives
2076-124
Storwize V7000 Unified control enclosure for up to 24 2.5-inch (6.35
cm) drives
2076-312
Storwize V7000 Unified control enclosure for 3.5-inch drives (with two
10 Gbps iSCSI/FCoE Ethernet ports)
2076-324
Storwize V7000 Unified control enclosure for 2.5-inch drives (with two
10 Gbps iSCSI/FCoE Ethernet ports)
2076-212
Storwize V7000 Unified expansion enclosure for 3.5-inch drives
2076-224
Storwize V7000 Unified expansion enclosure for 2.5-inch drives
Table 71. Storwize V7000 Unified Gen2 model numbers
Machine
type/model
Description
2076-524
Storwize V7000 Unified control enclosure, with up to 24 2.5-inch (6.35
cm) drives
2076-12F
Storwize V7000 Unified expansion enclosure for up to 12 3.5-inch (8.89
cm) drives
2076-24F
Storwize V7000 Unified expansion enclosure for 2.5-inch drives
online. If you know the service address of a node canister, either use the service
assistant to verify that the state of at least one node canister is active, or if the
node canister is not active, use the LEDs to see if any node canister state is
active.
If there is not a node canister with a state of active, resolve the reason why it is
not in active state. If the state of all node canisters is candidate, then there is not
a clustered system to connect to. If the node state is service, see the topic that
contains information about fixing node errors.
service assistant using the service address or the technician port of a node
canister, log in to find the node and system addresses on the Access tab of the
Node Detail table.
and that the port is working. Use the Ethernet LEDs to understand the port
status.