Control Enclosure Battery Leds - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

Results
To review the status of the control enclosure batteries, see Table 94.
266
Storwize V7000 Unified: Problem Determination Guide 2073-720
Table 93. System status and fault LEDs (continued)
System status
LED
Fault LED
On
On
Flashing
Off
Flashing
On
Any
Flashing
Table 94. Control enclosure battery LEDs
Battery Good
Battery Fault
+ -
+ -
On
Off
Flashing
off
Off
On
Status
Action
Code is active
The node canister cannot become active
and is in starting
in a system. There are no detected
state. However, it
problems on the node canister itself.
does not have
However, it cannot connect to enough
enough resources
resources to safely form a system.
to form the
Follow the procedure to fix the node
system.
errors. Go to "Procedure: Fixing node
errors" on page 271.
Code is active.
Create a system on the node canister, or
Node state is
add the node canister to the system. If
candidate.
the other node canister in the enclosure
is in active state, it automatically adds
this node canister into the system. A
node canister in this state can be
managed using the service assistant.
Code is active.
The node canister cannot become active
Node state is
in a system. Several problems can exist:
service.
hardware problem, a problem with the
environment or its location, or
problems with the code or data on the
canister. Follow the procedure to fix the
node errors. Go to "Procedure: Fixing
node errors" on page 271.
The node canister
The fix procedures in the management
is being
GUI might have identified the
identified so that
component because it requires
you can locate it.
servicing. Continue to follow the fix
procedures. The service assistant has a
function to identify node canisters. If
the identification LED is on in error,
use the service assistant node actions to
turn off the LED.
Description
Battery is good and fully
charged.
Battery is good but not fully
charged. The battery is either
charging or a maintenance
discharge is in process.
Nonrecoverable battery fault.
Action
None
None
Replace the battery. If
replacing the battery
does not fix the issue,
replace the power supply
unit.

Advertisement