7. Push the power supply unit back into the enclosure until the handle starts to
move.
8. Finish inserting the power supply unit in the enclosure by closing the handle
until the locking catch clicks into place.
9. Reattach the power cable and cable retention bracket.
10. Turn on the power switch to the power supply unit.
What to do next
If required, return the power supply. Follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.

Replacing the battery in a node canister

Remove and replace the battery in a node canister.
Replacing the battery in a Storwize V7000 Gen2 node canister
To replace a faulty battery with a new one received from customer replaceable unit
(CRU) or field replaceable unit (FRU) stock, use this procedure.
About this task
CAUTION:
The battery is a lithium ion battery. To avoid possible explosions, do not burn.
Exchange only with the approved part. Recycle or discard the battery as
instructed by local regulations. (C007a)
To replace a battery:
Procedure
1. Identify the node canister with the faulty battery by following the procedure
"Procedure: Understanding the Storwize V7000 Gen2 system status from the
LEDs" on page 256.
2. Follow the procedure "Procedure: Removing a Storwize V7000 Gen2 node
canister" on page 279 to remove the node canister with the faulty battery.
3. Open the lid of the canister, as described in "Procedure: Removing and
replacing the lid of a Storwize V7000 Gen2 node canister" on page 285.
4. Spread the two blue battery latches outward as shown in Figure 92 on page
316. Raise open both latching arms of the battery simultaneously to disconnect
the battery.
Chapter 5. Control enclosure
315