Table 120. Upgrade error codes and recommended actions (continued)
Error
Code
Explanation
019D
Check the system health.
019E
Internal error - cluster or node not
provided.
019F
CIM restart failed.
01A0
Failed to reboot.
01A1
Internal upgrade error.
01A2
A GPFS command has failed.
01A3
Unable to uninstall CNCSM
callbacks.
01A4
Unable to stop backup jobs.
01A5
Backup cron jobs are running.
01A6
Unable to install CNCSM callbacks. Contact IBM Remote Technical Support.
01A7
Internal vital product data (VPD)
error.
01A8
Check the health of management
service.
Action
1. Use lsnode to check the status of
CTDB and GPFS for the nodes.
Reboot the unhealthy node and wait
for the node to be up again. Then,
again check the health of the node
with lsnode.
2. Contact IBM Remote Technical
Support.
Contact IBM Remote Technical Support.
Contact IBM Remote Technical Support.
Determine the cause of the failed reboot:
1. Check console of system if able. See if
the system is hung in BIOs or during
boot.
2. Check cabling of system.
3. Check light path diagnostic for error
indications. .
4. Reboot the system from console and
restart upgrade.
5. Contact IBM Remote Technical
Support.
Contact IBM Remote Technical Support.
Contact IBM Remote Technical Support.
Contact IBM Remote Technical Support.
1. Check the status of the backups by
typing lsjobstatus -j backup.
2. Attempt to stop backups by typing
stopbackup --all.
3. Contact IBM Remote Technical
Support.
1. Check the condition of tasks by
typing lstask -t cron.
2. Attempt to remove the backup by
typing rmtask StartBackupTSM.
3. Contact IBM Remote Technical
Support.
Contact IBM Remote Technical Support.
1. Attempt to start the management
service with startmgtsrv on active
management node
2. Contact IBM Remote Technical
Support.