User Definable Memory Map Default Values - GE MM3 Instruction Manual

Motor manager 3
Hide thumbs Also See for MM3:
Table of Contents

Advertisement

6.4 APPLICATIONS
For convenience default User Map values have been added. However, the User Definable Memory Map is still
fully customizable. The defaults are separated into three sections. Regular Polling data items, data that is read
when a Trip, Stop or Alarm occurs, and data that can be monitored as time permits.
Table 6–11: MM3 MEMORY MAP USER DEFINABLE OUTPUTS (Sheet 1 of 2)
REGULAR ADDRESS
MODICON
DEC
30021
20
30022
21
30023
22
30027
26
30028
27
30029
28
30035
34
30036
35
30037
36
30049
48
30050
49
30051
50
30052
51
30053
52
30054
53
6
30055
54
30056
55
30017
16
30020
19
30034
33
30057
56
30058
57
30059
58
30081
80
30082
81
30083
82
30084
83
30085
84
30086
85
30087
86
Shading codes:
6-16
DESCRIPTION
HEX
0014
General Alarm Active Status Flags 1
0015
General Alarm Active Status Flags 2
0016
Interlock Alarm Active Status Flags
001A
Interlock Start Block Status Flags
001B
Trip Active Status Flags 1
001C
Trip Active Status Flags 2
0022
Command Mode
0023
Drive Status
0024
Motor Mode
0030
Phase Current Scale Factor
0031
Phase A Current
0032
Phase B Current
0033
Phase C Current
0034
Ground Current
0035
Motor Load
0036
Thermal Capacity
0037
Current Unbalance
0010
Switch Input Status
0013
Operation Status Flags
0021
Cause of Stop
0038
Acceleration Time
0039
Last Starting Current
003A
O/L Time to Trip
0050
Cause of Trip
0051
Time to Reset
0052
Pre Trip Phase A Current
0053
Pre Trip Phase B Current
0054
Pre Trip Phase C Current
0055
Pre Trip Ground Current
0056
Cause of Last Trip
Regular Polling
Upon a Trip, Alarm, Stop
Monitor as time permits
MM3 Motor Manager 3

6.4.4 USER DEFINABLE MEMORY MAP DEFAULT VALUES

REGISTER
STEP
VALUE
VALUE
RANGE
6 COMMUNICATIONS
USER MAP
UNITS
DEFAULT
AND
FORMAT
ADDRESS
SCALE
(HEX)
F104
100
F105
101
F106
102
F106
103
F107
104
F108
105
F6
106
F7
107
F8
108
F1
109
F1
10A
F1
10B
F1
10C
F1
10D
% FLC
F1
10E
%
F1
10F
%
F1
110
F100
111
F103
112
F5
113
0.1 x s
F1
114
F1
115
F1
116
F9
117
min.
F1
118
F1
119
F1
11A
F1
11B
F1
11C
F1
11D
GE Power Management

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motor manager 3

Table of Contents