6 COMMUNICATIONS
Table 6–12: MODBUS MEMORY MAP (Sheet 16 of 19)
REGISTER
GROUP
MODICON
ADDRESS
DEC
PROGRAM-
44552
4551
MABLE
44553
4552
INPUTS
44554
4553
continued
44555
4554
44556
4555
44557
4556
↓
↓
44560
4559
PROCESS
44561
4560
INTERLOCK
44562
4561
NAMES
44563
4562
44564
4563
44565
4564
44566
4565
44567
4566
44568
4567
44569
4568
44570
4569
44571
4570
↓
↓
44576
4575
44577
4576
44578
4577
44579
4578
44580
4579
44581
4580
44582
4581
44583
4582
44584
4583
44585
4584
44586
4585
44587
4586
↓
↓
44592
4591
44593
4592
44594
4593
44595
4594
44596
4595
44597
4596
44598
4597
44599
4598
44600
4599
Notes:
* – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
GE Power Management
DESCRIPTION
HEX
11C7 Interlock 8 Switch Type
11C8 Interlock 9 Switch Type
11C9 Interlock 10 Switch Type
11CA Ground Alarm Delay on Start
11CB Ground Trip Delay on Start
11CC ...Reserved...
↓
↓
11CF
...Reserved...
11D0 Process Interlock E Name characters 1 and 2
11D1 Process Interlock E Name characters 3 and 4
11D2 Process Interlock E Name characters 5 and 6
11D3 Process Interlock E Name characters 7 and 8
11D4 Process Interlock E Name characters 9 & 10
11D5 Process Interlock E Name characters 11 & 12
11D6 Process Interlock E Name characters 13 & 14
11D7 Process Interlock E Name characters 15 & 16
11D8 Process Interlock E Name characters 17 & 18
11D9 Process Interlock E Name characters 19 & 20
11DA ...Reserved...
↓
↓
11DF
...Reserved...
11E0
Process Interlock F Name characters 1 and 2
11E1
Process Interlock F Name characters 3 and 4
11E2
Process Interlock F Name characters 5 and 6
11E3
Process Interlock F Name characters 7 and 8
11E4
Process Interlock F Name characters 9 & 10
11E5
Process Interlock F Name characters 11 & 12
11E6
Process Interlock F Name characters 13 & 14
11E7
Process Interlock F Name characters 15 & 16
11E8
Process Interlock F Name characters 17 & 18
11E9
Process Interlock F Name characters 19 & 20
11EA
...Reserved...
↓
↓
11EF
...Reserved...
11F0
Process Interlock G Name characters 1 and 2
11F1
Process Interlock G Name characters 3 and 4
11F2
Process Interlock G Name characters 5 and 6
11F3
Process Interlock G Name characters 7 and 8
11F4
Process Interlock G Name characters 9 & 10
11F5
Process Interlock G Name characters 11 & 12
11F6
Process Interlock G Name characters 13 & 14
11F7
Process Interlock G Name characters 15 & 16
MM3 Motor Manager 3
6.5 MEMORY MAP
REGISTER
STEP
UNITS
FOR-
VALUE
VALUE
AND
MAT
RANGE
SCALE
0-1
1
-
F30
0-1
1
-
F30
0-1
1
-
F30
1-60
1
s
F1
0-100
1
s
F1
...
...
...
...
↓
↓
↓
...
...
...
...
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
...
...
...
...
↓
↓
↓
...
...
...
...
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
...
...
...
...
↓
↓
↓
...
...
...
...
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
FACTORY
DEFAULT
VALUE
(CONVERTED)
0 = N.O.
0 = N.O.
0 = N.O.
10
10
...
↓
↓
...
'PR'
'OC'
'ES'
'S '
'IN'
'TE'
'RL'
'OC'
'K '
'E '
...
↓
↓
...
'PR'
'OC'
6
'ES'
'S '
'IN'
'TE'
'RL'
'OC'
'K '
'F '
...
↓
↓
...
'PR'
'OC'
'ES'
'S '
'IN'
'TE'
'RL'
'OC'
6-33
Need help?