6 COMMUNICATIONS
Table 6–12: MODBUS MEMORY MAP (Sheet 14 of 19)
REGISTER
GROUP
MODICON
ADDRESS
DEC
COMMANDS
44458
4457
continued
44459
4458
44460
4459
44461
4460
44464
4463
UNDER/OVER
44465
4464
VOLTAGE
44466
4465
PROTECTION
44467
4466
44468
4467
44469
4468
44470
4469
44471
4470
44472
4471
44473
4472
44480
4479
PROG.
44481
4480
MESSAGE
44482
4481
44483
4482
44484
4483
44485
4484
44486
4485
44487
4486
44488
4487
44489
4488
44490
4489
44491
4490
44492
4491
44493
4492
44494
4493
44495
4494
44496
4495
44497
4496
44498
4497
44499
4498
44500
4499
44501
4500
44502
4501
Notes:
* – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
GE Power Management
DESCRIPTION
HEX
1169
Command Data 8
116A
Command Data 9
116B Command Data 10
116C ...Reserved...
116F
...Reserved...
1170
Undervoltage Alarm Level
1171
Undervoltage Alarm Delay
1172
Undervoltage Trip Level
1173
Undervoltage Trip Delay
1174
Overvoltage Alarm Level
1175
Overvoltage Alarm Delay
1176
Overvoltage Trip Level
1177
Overvoltage Trip Delay
1178
...Reserved...
117F
...Reserved...
1180
Programmable message characters 1 and 2
1181
Programmable message characters 3 and 4
1182
Programmable message characters 5 and 6
1183
Programmable message characters 7 and 8
1184
Programmable message characters 9 and 10
1185
Programmable message characters 11 & 12
1186
Programmable message characters 13 & 14
1187
Programmable message characters 15 & 16
1188
Programmable message characters 17 & 18
1189
Programmable message characters 19 & 20
118A
Programmable message characters 21 & 22
118B
Programmable message characters 23 & 24
118C Programmable message characters 25 & 26
118D Programmable message characters 27 & 28
118E
Programmable message characters 29 & 30
118F
Programmable message characters 31 & 32
1190
Programmable message characters 33 & 34
1191
Programmable message characters 35 & 36
1192
Programmable message characters 37 & 38
1193
Programmable message characters 39 & 40
1194
...Reserved...
1195
...Reserved...
MM3 Motor Manager 3
6.5 MEMORY MAP
REGISTER
STEP
UNITS
FOR-
VALUE
VALUE
AND
MAT
RANGE
SCALE
0-65535
1
---
F1
0-65535
1
---
F1
0-65535
1
---
F1
...
...
...
...
...
...
...
...
0-691
1
V
F1 *
1-60
1
s
F1
0-691
1
V
F1 *
1-60
1
s
F1
0-691
1
V
F1 *
1-60
1
s
F1
0-691
1
V
F1 *
1-60
1
s
F1
...
...
...
...
...
...
...
...
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
32-255
1
ASCII
F10
...
...
...
...
...
...
...
...
FACTORY
DEFAULT
VALUE
(CONVERTED)
0
0
0
...
...
691 = 0FF
10
691 = 0FF
10
691 = 0FF
10
691 = 0FF
10
...
...
"PR"
"OG"
"RA"
"MM"
"AB"
"LE"
6
" M"
"ES"
"SA"
"GE"
"SA"
"MP"
"LE"
" T"
"EX"
"T "
" "
" "
" "
" "
...
...
6-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motor manager 3