6.5 MEMORY MAP
Table 6–12: MODBUS MEMORY MAP (Sheet 3 of 19)
GROUP
MODICON
TRIP DATA
30085
continued
30086
30087
30088
MAINTENANCE
30089
TIMERS
30090
30110
30110
MAINTENANCE
30097
COUNTERS
30098
30099
30100
30101
30102
30103
30104
30105
30106
30107
30108
30109
30110
6
30111
30112
TIMERS
30113
30114
30115
30116
30117
30118
30119
30120
30121
30122
30123
30128
DEBUG
30129
DATA
30130
30131
30132
Notes:
* – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
6-20
REGISTER
ADDRESS
DESCRIPTION
DEC
HEX
84
0054
Pre Trip Phase C Current
85
0055
Pre Trip Ground Current
86
0056
Cause of Last Trip
87
0057
...Reserved...
88
0058
Running Time
89
0059
Stopped Time
109
006D ...Reserved...
109
006D ...Reserved...
96
0060
Number of Starts - high order
97
0061
Number of Starts - low order
98
0062
Total Trips
99
0063
Overload Trips
100
0064
Thermistor Trips
101
0065
Ground Fault Trips
102
0066
Single Phase Trips
103
0067
Acceleration Time Trips
104
0068
Undercurrent Trips
105
0069
Underpower Trips
106
006A
Stalled Rotor Trips
107
006B
Control Command Trips
108
006C Interlock Counter
109
006D ...Reserved...
110
006E
...Reserved...
111
006F
...Reserved...
112
0070
Undervoltage Restart Timer
113
0071
AUX Relay 1 Post Contactor A Delay Timer
114
0072
Transfer Timer
115
0073
First Stage Timer
116
0074
Second Stage Timer
117
0075
Start Inhibit Timer
118
0076
AUX 2 Post Contactor A Delay Timer
119
0077
AUX 1+2 Pre Con. A Delay Timer
120
0078
AUX 1 Pre. Con. A Post Start Delay Timer
121
0079
AUX 2 Pre. Con. A Post Start Delay Timer
122
007A
...Reserved...
127
007F
...Reserved...
128
0080
ADC Reference
129
0081
Thermistor Reading
130
0082
Power Loss Fine Time
131
0083
Power Loss Coarse Time
MM3 Motor Manager 3
REGISTER
VALUE
RANGE
---
---
---
...
---
---
...
...
---
---
---
---
---
---
---
---
---
---
---
---
---
...
...
...
---
---
---
---
---
---
---
---
---
---
...
...
---
---
---
---
6 COMMUNICATIONS
FACTORY
STEP
UNITS
FOR-
DEFAULT
VALUE
AND
MAT
VALUE
SCALE
(CONVERTED)
---
**
F1
---
0.1 x A
F1
---
---
F1
...
...
...
---
hr.
F1
---
hr.
F1
...
...
...
...
...
...
---
---
F2
---
---
F2
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
---
---
F1
...
...
...
...
...
...
...
...
...
---
0.1 x s
F1
---
s
F1
---
0.5 x s
F1
---
0.5 x s
F1
---
0.5 x s
F1
---
s
F1
---
s
F1
---
s
F1
---
s
F1
---
s
F1
...
...
...
...
...
...
---
---
F1
---
kOhms
F1
---
10 ms
F1
---
0.1 min.
F1
GE Power Management
N/A
N/A
N/A
...
0
0
...
...
0
0
0
0
0
0
0
0
0
0
0
0
0
...
...
...
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
...
...
N/A
N/A
N/A
N/A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MM3 and is the answer not in the manual?

This manual is also suitable for:

Motor manager 3

Table of Contents