GE MM3 Instruction Manual page 114

Motor manager 3
Hide thumbs Also See for MM3:
Table of Contents

Advertisement

6.5 MEMORY MAP
Table 6–12: MODBUS MEMORY MAP (Sheet 9 of 19)
GROUP
MODICON
CONFIG.
44245
INPUTS
44246
continued
44247
44248
44249
44250
44251
44252
44253
44254
44255
44256
44257
44258
44259
44260
44261
44262
44263
44264
44265
44266
44267
6
44268
44269
44270
44271
44272
PROCESS
44273
INTERLOCK
44274
NAMES
44275
44276
44277
44278
44279
44280
44281
44282
44283
44284
44285
44286
Notes:
* – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
6-26
REGISTER
ADDRESS
DESCRIPTION
DEC
HEX
4244
1094
Instantaneous Alarm
4245
1095
...Reserved...
4246
1096
...Reserved...
4247
1097
...Reserved...
4248
1098
Interlock Input 8 Function
4249
1099
Startup Override Delay
4250
109A
Running Override Delay
4251
109B
Operation
4252
109C Instantaneous Alarm
4253
109D ...Reserved...
4254
109E
...Reserved...
4255
109F
...Reserved...
4256
10A0 Interlock Input 9 Function
4257
10A1 Startup Override Delay
4258
10A2 Running Override Delay
4259
10A3 Operation
4260
10A4 Instantaneous Alarm
4261
10A5 ...Reserved...
4262
10A6 ...Reserved...
4263
10A7 ...Reserved...
4264
10A8 Interlock Input 10 Function
4265
10A9 Startup Override Delay
4266
10AA Running Override Delay
4267
10AB Operation
4268
10AC Instantaneous Alarm
4269
10AD Auto Mode Definition
4270
10AE
Local Isolator
4271
10AF
Auto Permissive Indication
4272
10B0
Process Interlock A Name characters 1 and 2
4273
10B1
Process Interlock A Name characters 3 and 4
4274
10B2
Process Interlock A Name characters 5 and 6
4275
10B3
Process Interlock A Name characters 7 & 8
4276
10B4
Process Interlock A Name characters 9 & 10
4277
10B5
Process Interlock A Name characters 11 & 12
4278
10B6
Process Interlock A Name characters 13 & 14
4279
10B7
Process Interlock A Name characters 15 & 16
4280
10B8
Process Interlock A Name characters 17 & 18
4281
10B9
Process Interlock A Name characters 19 & 20
4282
10BA Serial Permissive
4283
10BB Start Block Alarm
4284
10BC Command mode change when running
4285
10BD ...Reserved...
MM3 Motor Manager 3
6 COMMUNICATIONS
REGISTER
STEP
UNITS
FOR-
VALUE
VALUE
AND
MAT
RANGE
SCALE
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
...
...
...
0-34
1
---
F17
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
...
...
...
0-34
1
---
F17
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
...
...
...
0-34
1
---
F17
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
0-1
1
---
F27
0-1
1
---
F14
0-1
1
---
F16
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
0-1
1
---
F14
0-1
1
---
F14
0-1
1
---
F14
...
...
...
...
GE Power Management
FACTORY
DEFAULT
VALUE
(CONVERTED)
0 = DISABLE
...
...
...
0 = NOT USED
0
0
0 = IL STOP
0 = DISABLE
...
...
...
0 = NOT USED
0
0
0 = IL STOP
0 = DISABLE
...
...
...
0 = NOT USED
0
0
0 = IL STOP
0 = DISABLE
0 = SERIAL
0 = DISABLE
0 = MANUAL
"PR"
"OC"
"ES"
"S "
"IN"
"TE"
"RL"
"OC"
"K "
"A "
0 = DISABLE
0 = DISABLE
0 = DISABLE
...

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motor manager 3

Table of Contents