6.5 MEMORY MAP
Table 6–12: MODBUS MEMORY MAP (Sheet 11 of 19)
GROUP
MODICON
FIELD STOP
44337
44338
44339
44340
44341
44342
44343
44344
ANALOG
44345
INPUT
44346
44347
44348
44349
44350
44351
44352
44353
44354
44355
44356
44357
44358
44359
6
44360
44361
44362
44363
44364
44365
44366
44367
44368
44369
44370
44371
44372
44373
Notes:
* – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
6-28
REGISTER
ADDRESS
DESCRIPTION
DEC
HEX
4336
10F0
Field Stop Mode
4337
10F1
ESD Stop Mode
4338
10F2
ESD Indication
4339
10F3
Faceplate Stop
4340
10F4
Process Stop
4341
10F5
...Reserved...
4342
10F6
...Reserved...
4343
10F7
...Reserved...
4344
10F8
Analog Input Name characters 1 and 2
4345
10F9
Analog Input Name characters 3 and 4
4346
10FA
Analog Input Name characters 5 and 6
4347
10FB
Analog Input Name characters 7 and 8
4348
10FC
Analog Input Name characters 9 and 10
4349
10FD
Analog Input Name characters 11 and 12
4350
10DE Analog Input Name characters 13 and 14
4351
10FF
Analog Input Name characters 15 and 16
4352
1100
Analog Input Name characters 17 and 18
4353
1101
Analog Input Name characters 19 and 20
4354
1102
Analog Input Units characters 1 and 2
4355
1103
Analog Input Units characters 3 and 4
4356
1104
Analog Input Units characters 5 and 6
4357
1105
Analog Input Units characters 7 and 8
4358
1106
Analog Input Units characters 9 and 10
4359
1107
Minimum Scale
4360
1108
Maximum Scale
4361
1109
Analog Alarm Low Level
4362
110A
Analog Alarm Low Delay
4363
110B
Analog Alarm High Level
4364
110C Analog Alarm High Delay
4365
110D Analog Trip Low Level
4366
110E
Analog Trip Low Delay
4367
110F
Analog Trip High Level
4368
1110
Analog Trip High Delay
4369
1111
Analog Low Override Delay
4370
1112
Analog High Override Delay
4371
1113
...Reserved...
4372
1114
...Reserved...
MM3 Motor Manager 3
6 COMMUNICATIONS
REGISTER
STEP
UNITS
FOR-
VALUE
VALUE
AND
MAT
RANGE
SCALE
0-1
---
F19
0-1
---
F19
0-1
---
F29
0-1
---
F19
0-1
---
F19
...
...
...
...
...
...
...
...
...
...
...
...
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
32-127
1
ASCII
F10
0-20000
10
---
F1
10-20000
10
---
F1
1-20001
1
---
F1*
1-600
1
s
F1
1-20001
1
---
F1*
1-600
1
s
F1
1-20001
1
---
F1*
1-600
1
s
F1
1-20001
1
---
F1*
1-600
1
s
F1
1-126
1
s
F1*
1-126
1
s
F1*
...
...
...
...
...
...
...
...
GE Power Management
FACTORY
DEFAULT
VALUE
(CONVERTED)
0=UNLATCHED
0=UNLATCHED
1=ON/Healthy
0=UNLATCHED
0=UNLATCHED
...
...
...
"AN"
"AL"
"OG"
" I"
"NP"
"UT"
" "
" "
" "
" "
"UN"
"IT"
"S "
0
1000
65535 = OFF
5
65535 = OFF
5
65535 = OFF
5
65535 = OFF
5
5
5
...
...

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motor manager 3

Table of Contents