Water Supply Housing

Figure 273 Water supply housing and coolant
port seal
1. Position coolant port seal into machined recess at
water supply housing.
Figure 274 Water supply housing bolts
1.
Bolt, M10 x 25 (4)
2. Install water supply housing and secure with four
water supply housing bolts (M10 x 25).
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.
FRONT COVER AND RELATED COMPONENTS
Follow all warnings, cautions, and notes.
© 2009 Navistar, Inc.
Figure 275 Torquing the water supply housing
bolts
3. Tighten all bolts to the standard torque value
(General Torque Guidelines, page445 ) .

Alternator Bracket

Figure 276 Alternator bracket
1.
Bolt, M10 x 120 (2)
2.
Alternator bracket
3.
Bolt, M8 x 100 (2)
1. Position alternator bracket to backside of front
cover and install two bolts (M10 x 120) and hex
flange nuts (M10) finger tight.
2. Install the two remaining bolts (M8 x 100) and hex
flange nuts (M8) finger tight.