Message
Watchdog %1 Failed to
Capture Screen.
(%1 = OS Watchdog or
Loader Watchdog)
Watchdog %1 Screen
Capture Occurred.
(%1 = OS Watchdog or
Loader Watchdog)
Invalid or Unsupported
firmware or software was
detected on System n. (n =
system serial number)
Severity
Description
Error
An operating-system error has
occurred, and the screen capture
failed.
Error
An operating-system error has
occurred, and the screen capture
was successful.
Error
IMM firmware failover has occurred
and IMM has reverted to a previous
version of the firmware.
Action
1. Reconfigure the watchdog timer
to a higher value.
2. Make sure that the IMM
Ethernet over USB interface is
enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for the
operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
6. Update the IMM firmware.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
1. Reconfigure the watchdog timer
to a higher value.
2. Make sure that the IMM
Ethernet over USB interface is
enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for the
operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
1. Check the IBM support website
for an applicable firmware
update that applies to the rack
server.
2. Reboot IMM and verify the IMM
is running correct firmware level
after firmware update.