Table 6. DSA messages
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, Type 7377 server," on page 125 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
089-801-xxx
CPU
089-802-xxx
CPU
62
IBM System x3630 M3 Type 7377: Problem Determination and Service Guide
Test
State
Description
CPU Stress
Aborted
Internal program
Test
error.
CPU Stress
Aborted
System
Test
resource
availability error.
Action
1. Turn off and restart the system.
2. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
3. Run the test again.
4. Make sure that the system firmware is at the
latest level. The installed firmware level is shown
in the diagnostic event log in the Firmware/VPD
section for this component. For more information,
see "Updating the firmware" on page 233.
5. Run the test again.
6. Turn off and restart the system if necessary to
recover from a hung state.
7. Run the test again.
8. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
3. Run the test again.
4. Make sure that the system firmware is at the
latest level. The installed firmware level is
shown in the diagnostic event log in the
Firmware/VPD section for this component. For
more information, see "Updating the firmware"
on page 233.
5. Run the test again.
6. Turn off and restart the system if necessary to
recover from a hung state.
7. Run the test again.
8. Make sure that the system firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see "Updating the firmware"
on page 233.
9. Run the test again.
10. If the failure remains, go to the IBM Web site for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.