Installing The System Fan Cage - IBM x3630 M3 7377 Problem Determination And Service Manual

Hide thumbs Also See for x3630 M3 7377:
Table of Contents

Advertisement

2. Turn off the server and peripheral devices and disconnect all power cords and
3. Remove the cover (see "Removing the cover" on page 145).
4. (For 3.5-inch hard disk drive models only) Remove the signal cables.
5. Grasp the system fan cage by the blue grip points.
6. Press the retention latches toward each other; then, lift the system fan cage out
7. If you are instructed to return the system fan cage, follow all packaging

Installing the system fan cage

For proper cooling, the server requires that all fans in the server be operating at all
times.
Attention:
v To ensure proper server operation, if a fan fails, replace the fan immediately.
v Make sure the power cable on the backplane is well-routed so it will not block the
To install the system fan cage, complete the following steps:
1. Align the system fan cage with the guide rails on the fan cage bracket.
2. If you have removed any cable(s), connect them all except the signal cable.
3. Lower the system fan cage into the fan cage bracket until the system fan cage
external cables.
of the server.
instructions, and use any packaging materials for shipping that are supplied to
you.
fan cage while installing.
clicks into place.
Notes:
a. Make sure no cables are pinched.
b. (For 3.5-inch hard disk drive models only) It will be easier for the installation
if you temporary remove the power cable on the hot-swap backplane.
Chapter 5. Removing and replacing server components
191

Advertisement

Table of Contents
loading

Table of Contents