IBM x3630 M3 7377 Problem Determination And Service Manual page 50

Hide thumbs Also See for x3630 M3 7377:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, Type 7377 server," on page 125 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
0058008
DIMM failed memory test
0058015
Start to activate spare memory
channel
00580A1
Invalid DIMM population for mirroring
mode
00580A4
Memory population changed
32
IBM System x3630 M3 Type 7377: Problem Determination and Service Guide
Action
Note: Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1. Check the IBM support website for an applicable retain tip
or firmware update that applies to this memory error.
2. Manually re-enable all affected DIMMs if the server
firmware version is older than UEFI v1.10. If the server
firmware version is UEFI v1.10 or newer, disconnect and
reconnect the server to the power source and restart the
server.
3. Swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different
memory channel or microprocessor (see "Installing a
memory module" on page 162 for memory population).
4. If the problem is related to a DIMM, replace the failing
DIMM (see "Removing a memory module (DIMM)" on
page 161 and "Installing a memory module" on page 162).
5. (Trained service technician only) If the problem occurs on
the same DIMM connector, check the DIMM connector. If
the connector contains any foreign material or is
damaged, replace the system board (see "Removing the
system board" on page 228 and "Installing the system
board" on page 230).
6. (Trained service technician only) Remove the affected
microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the
system board (see "Removing the system board" on page
228 and "Installing the system board" on page 230).
7. (Trained service technician only) If the problem is related
to microprocessor socket pins, replace the system board
(see "Removing the system board" on page 228 and
"Installing the system board" on page 230).
8. (Trained Service technician only) Replace the affected
microprocessor (see "Removing a microprocessor and
heat sink" on page 221 and "Installing a microprocessor
and heat sink" on page 223).
Information only. A failed DIMM has been detected to activate
the memory online-spare feature. Check the event log for
uncorrected DIMM failure events.
Note: Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1. If a fault LED is lit, resolve the failure.
2. Install the DIMMs in the correct sequence (see "Installing
a memory module" on page 162).
Information only. Memory has been added, moved, or
changed.

Advertisement

Table of Contents
loading

Table of Contents