Remove Pcb Assembly; Figure 11-17. Battery Power Wires For Battery Interface; Figure 11-18. Communication Connector For Battery Interface; Figure 11-19. Atf Thermistor Disconnect - Saros 9400R-SEQ Operators & Service Manual

Table of Contents

Advertisement

Operator & Service Manual
NOTE: Always use ESD Controls when handling the PCB Assembly.
11.7.3.1 Loosen the Battery Power Wire screws and remove wires.
11.7.3.2 Disconnect the Compressor Thermistor wires.
11.7.3.3 Disconnect the Halls Effect wire.
11.7.3.4 Loosen the Compressor Power screws and remove the wires.
2--Disconnect
1-Loosen
11.7.3.5 Disconnect Battery Communication Connector.
11.7.3.6 Disconnect the ATF Stepper Motor Connector from the
PCB.
11.7.3.9 Cut the cable tie and remove the Flow Tube from the
Product Tank.
NOTE: It is recommended to cap this outlet using a piece of
tape during the repair process. Do not leave the plug open to
atmosphere longer than it takes to preform the repair process. If
this port is exposed longer than 24 hours, it must be completely
sealed to prevent damage to the ATF. If just exposed during repair,
tape is sufficient to prevent any damage.
11.7.3.10 Remove 2 screws on the Left STRUT (9779-SEQ).
11.7.3.11 Remove 2 screws on the Right STRUT (9780-SEQ).

11.7.3 REMOVE PCB ASSEMBLY

Figure 11-17. Battery Power Wires for Battery Interface

Fan Connector
(red and black
wires)
ATF Thermistor
(blue wires)
ATF stepper
motor connector
(4 pin)
4-Loosen

Figure 11-18. Communication Connector for Battery Interface

ATF Stepper Motor Power, Fan Disconnect, ATF Thermistor

Figure 11-19. ATF Thermistor Disconnect

3--Disconnect
Battery communications
connector (5 pin)
• Cut Cable Tie
• Remove Tubing
• Cap Brass
Fitting
9735-SEQ H | 53