lates charge, the charging current required will eventually fall. Battery charging will cease when the Battery voltage is greater
than 16V, charge current is less than 0.66A, and relative charge is greater than 93%.
The software will only charge when the Battery temperature is at or below 40°C. The software will always run the cooling fan
whenever the charger is enabled. The Battery Charger is disabled and the cooling fan is set to maximum whenever the Battery
temperature exceeds 40°C. The Battery charger is disabled when temperature is less than 5°C.
All lithium ion batteries self-discharge at very low rates when not in use. SAROS Batteries are shipped from CAIRE Inc. in a
partially charged state (nominally 40%). Do not store the SAROS with the battery installed in the unit. Remove the battery from
the unit when storing to prevent damage to the battery and the unit. CAIRE Inc. recommends a first in, first out rotation of Battery
inventory for maximum service life.
WARNING: INDICATES A HAZARDOUS SITUATION THAT, IF NOT AVOIDED, COULD RESULT IN DEATH OR SERIOUS
INJURY.
WARNING: DO NOT OPEN OR HANDLE EXCEPT AT A STATIC FREE WORKSTATION. DO NOT REMOVE COVER WITHOUT
ESD PROTECTION.
WARNING: DO NOT STORE THE SAROS WITH THE BATTERY INSTALLED IN THE UNIT.
WARNING: WHEN PERFORMING SERVICE AND REPAIR PROCEDURES DO NOT TOUCH EXPOSED CIRCUITS DURING
THE MAINTENANCE. DO NOT TOUCH MOVING PARTS.
CAUTION: The SAROS contains electrostatic sensitive components.
9735-SEQ H | 25