11.8.2.7 Install the ATF Product Pipe onto the Product Tank with Silicone tubing and secure with Cable ties. Install the other
end onto the ATF with the Product Tube and Clamp as shown in figure below.
0.5" silicone tube
(SP6981-SEQ)
11.8.3.1 Attach RIGHT STRUT (9780-SEQ) with five screws (9912-1-SEQ) with and torque to 6.0 in-lbs.
NOTE: Top bulkhead screw not shown.
11.8.3.2 Rotate assembly, route the ATF wires (stepper motor
and ATF thermistor wires) under the slot of the LEFT STRUT
(9779-SEQ).
NOTE: Pre-install cable ties in rail holes prior to installation.
11.8.3.3 Secure the STRUT (9779-SEQ) with five screws and
torque the screws to 6.0 in-lb.
62 | 9735-SEQ H
cable tie
ATF product
x2 (6968-SEQ)
pipe (9342-SEQ)
Figure 11-48. Open SAROS
11.8.3 RAIL INSTALLATION
Figure 11-49. Right Strut
clamp x2
(9369-SEQ)
Slot in
rail
Figure 11-50. Route ATF wires
Figure 11-51. Secure
Operator & Service Manual
ATF product
tube (9797-SEQ)
ATF wires, verify
loop for proper
length
LEFT STRUT