11.8.7.2 Insert and secure the Battery Power and Compres-
sor Power Wires where shown. Use a flat blade screwdriver to
tighten and torque the screws to 4.4 in-lbs.
NOTE: Battery wire polarity indicated on the PCBA. Red is (+) and
Black is (-).
11.8.7.3 Connect the Thermistor Connector to the PCBA
11.8.7.4 Connect the Hall Effect Connector to the PCBA
NOTE: Ensure there is enough slack to the Hall Effect Wire
11.8.7.5 Connect the Fan Connector to the PCB and connect
flow tubing.