64 •
PROFINET IO 750-370
I/O Device Configuration
Module
PE_DIA_32
PE_DIA_16
PE_DIA_8
PE_DIA_0
Description
Configuration module for 32 digital inputs,
4 bytes are reserved in the input process
image of the I/O controller. The bit
information in the first byte is allocated to
the 2 bit diagnostics data of the configured
supply module. Remaining bit locations
(indicated in brackets with a positive sign)
can be allocated to the signal states of the
following I/O module having the
appropriate type of signal or the diagnostics
information of diagnostic capable I/O
modules. This is done by configuring the
DI_0, - DI_DIA_0 DO_DIA_0 or
PE_DIA_0 modules for the relevant I/O
modules.
Configuration module for 16 digital inputs,
2 bytes are reserved in the input process
image of the I/O controller. The bit
information in the first byte is allocated to
the 2 bit diagnostics data of the configured
supply module. Remaining bit locations
(indicated in brackets with a positive sign)
can be allocated to the signal states of the
following I/O module having the
appropriate type of signal or the diagnostics
information of diagnostic capable I/O
modules. This is done by configuring the
DI_0, - DI_DIA_0 DO_DIA_0 or
PE_DIA_0 modules for the relevant I/O
modules.
Configuration module for 8 digital inputs, 1
byte is reserved in the input process image
of the I/O controller. 2 bit are allocated to
the diagnostics data of the configured
supply module. Remaining bit locations
(indicated in brackets with a positive sign)
can be allocated to the signal states of the
following I/O module having the
appropriate type of signal or the diagnostics
information of diagnostic capable I/O
modules. This is done by configuring the
DI_0, - DI_DIA_0 DO_DIA_0 or
PE_DIA_0 modules for the relevant I/O
modules.
Configuration module for filling input
information previously reserved by
modules DI_32, PE_DIA_32,
Dx_DIA_32, DI_16, PE_DIA_16,
Dx_DIA_16, DI _8, PE_DIA_8 or
Dx_DIA_8. Care must be taken that the
number of previously reserved input and
output bits are sufficient to receive 2 bit
diagnostic information of the configured
I/O module (represented in brackets with a
negative sign).
Exemplary name
750-610 P-Supply,
2DIA(+30 BIT E),
DIA in E-PA
750-610 P- Supply,
2DIA(+14 BIT E),
DIA in E-PA
750-610 P- Supply,
2DIA(+6 BIT E),
DIA in E-PA
750-610* P- Supply,
2DIA(-2 BIT E),
DIA in E-PA
WAGO-I/O-SYSTEM 750
PROFINET IO