Parameter
Default value behavior of the
outputs
Process data format channel x
(x = 0.1)
Substitute output data channel x
(x = 0.1)
WAGO-I/O-SYSTEM 750
PROFINET IO
Configuration and Parameter Setting of the Modules
Value
according to the device settings*)
Outputs are set to 0
Outputs maintain the last valid value
Outputs take on their default value
according to the device settings*)
INTEL (LSB-MSB)
MOTOROLA (MSB-LSB)
*)
0x0000
– 0x7FFF
or
*)
0x0000
– 0xFFFF
*) Default settings
I/O Modules
Significance
In case the I/O controller does not supply valid
output data for the module or the group of modules
then
•
the set strategy on the side of the station
distributor applies (I/O device).
•
all outputs are immediately reset
•
all outputs maintain the last valid value
•
all outputs switch to their configured
substitute value
The process data will be transferred
•
transfer the settings of the I/O device.
•
Little Endian Format
•
Big Endian Format
If the switching of substitute values has been
selected as a fault strategy, the substitute output
data of the individual output channels can be
determined here.