CNC 4 2 2 0 M a c hi ne Too l Op e ra t ion an d Te st
Chuck mode 0
|
Chuck mode 2
Chuck mode 1
|
Chuck mode 3
Chuck mode "0": continuous output control mode of internal chuck; chuck mode "1": continuous
output control mode of external chuck; chuck mode "2": inching output control mode of internal
chuck; chuck mode "3": inching output control mode of external chuck
The difference between "0" and "2" of chuck clamping settings: if "2" is selected, main axis and
chuck are interlocked.
If the chuck clamping setting is "1", check the clamping in position signal. The principle of the four
working mode follows:
Chuck mode 0: while executing clamping instruction M12, open XS6-12 port and close XS6-13 port,
and check the clamping in position signal pin XS5-8. If the clamping signal is detected in the
clamping time of the chuck, the M12 instruction is executed; otherwise, send alarm info "chuck
clamping overtime".
Chuck mode 1: while executing clamping instruction M12, open XS6-13 port and close XS6-12 port,
and check the clamping in position signal pin XS5-7. If the clamping signal is detected in the
clamping time of the chuck, the M12 instruction is executed; otherwise, send alarm info "chuck
clamping overtime".
Chuck mode 2: while executing clamping instruction M12, open XS6-12 port and close XS6-13 port,
delay chuck clamping time and then clock the XS6-12 port, and check the clamping in position signal
pin XS5-8. If the signal is valid, the M12 instruction is executed; otherwise, send alarm info "chuck
clamping overtime".
Chuck mode 3: while executing clamping instruction M12, open XS6-13 port and close XS6-12 port,
delay chuck clamping time and then clock the XS6-13 port, and check the clamping in position signal
pin XS5-7. If the signal is valid, the M12 instruction is executed; otherwise, send alarm info "chuck
clamping overtime".
Note: when check the chuck clamping parameter settings: 0- do not check, do not interlock with
main axis, 1- check the clamping signal and interlock with main axis, 2- do not check the
clamping signal but interlock with main axis, 3- check the clamping signal but do not interlock
with main axis
13.8.3 TROUBLESHOOTING FOR CHUCK CONTROL
The chuck control is comparatively simple and its main I/O signals can be checked in the diagnosis
interface. Please check the relating signal if any fault occurs.
The output point state of M12 is shown below.
76
Need help?
Do you have a question about the ADT-CNC4220 and is the answer not in the manual?