Sign In
Upload
Manuals
Brands
Honeywell Manuals
Security System
VISTA-32FBPT
Honeywell VISTA-32FBPT Manuals
Manuals and User Guides for Honeywell VISTA-32FBPT. We have
4
Honeywell VISTA-32FBPT manuals available for free PDF download: Installation And Setup Manual, User Manual, Quick Manual, Quick Manual To User Functions
Honeywell VISTA-32FBPT Installation And Setup Manual (104 pages)
Commercial Fire and Burglary Partitioned Security System with Scheduling
Brand:
Honeywell
| Category:
Security System
| Size: 0.96 MB
Table of Contents
Table of Contents
3
List of Figures
5
Conventions Used in this Manual
6
UL864 (Commercial Fire) Compliance
7
General Requirements
7
Programming Field Settings for UL864 Compliance
7
Programming Field Settings for ULC304 Compliance
10
Section 1: General Description
11
SIA Installations
11
About the VISTA-32FBPT
11
Features
11
Guidelines for Wiring a System
15
Figure 1-1: Isolating Fire Devices from Burglary Devices
16
Section 2: Partitioning
17
Theory of Partitioning
17
Setting-Up a Partitioned System
17
Common Lobby Logic
17
Master Keypad Setup and Operation
19
Section 3: Installing the Control
21
Mounting the Control in the Standard Cabinet for Commercial Fire Only Applications
21
Figure 3-1: Installing the Lock
21
Figure 3-2: Separation of Circuits
22
Figure 3-3: Mounting the PC Board
22
Mounting the Control in the Attack-Proof Cabinet (Suitable for Commercial Fire/Commercial Burglary Applications)
23
Figure 3-4: Cabinet Attack Resistance Considerations
23
Figure 3-5: Commercial Fire Installation Using Attack-Proof Cabinet
24
Installing the Keypads
25
Figure 3-6: Mounting the PC Board in Attack-Proof Cabinet
25
Figure 3-7: Keypad Connections to Control Panel
25
Figure 3-8. ECP Isolator Wiring
26
Installing External Sounders
27
Figure 3-9. Using a Supplementary Power Supply
27
Auxiliary Relay Connections
30
Telephone Line Connections
31
Figure 3-10: Wiring Auxiliary Relay for Alarm Activation
31
Figure 3-11: Wiring Auxiliary Relay for Smoke Detector Reset
31
Main Dialer Connections
32
Wiring Burglary and Panic Devices to Zones 1-8
33
Figure 3-12: 2-Wire Smoke Detector on Zone 1 (for Zone 2 Use Terminals 17 and 18)
34
Figure 3-13: 4-Wire Smoke Detectors
35
Installing V-Plex Devices
36
Figure 3-14: Wiring a Normally Closed Sensor Loop for Tamper Supervision
36
Figure 3-15: Wiring a Normally Open Sensor Loop for Tamper Supervision
36
Figure 3-16: Polling Loop Connections to the Control Panel
37
Figure 3-17: Polling Loop Connections Using One 4297 Extender Module
38
Figure 3-18: Polling Loop Connections Using Multiple Extender Modules
38
Polling Loop Supervision
38
Power Supply
38
Wireless Zone Expansion
39
Figure 3-19: Installing the 5881ENHC with Tamper Protection
40
Figure 3-20: 5881ENHC RF Receiver (Cover Removed)
41
Installing Output Devices
42
Figure 3-21: 4204 Relay Module
43
Figure 3-22: 4204CF Relay Module
43
Dip Switch Settings
43
Installing a Remote Keyswitch
44
Installing a Remote Keypad Sounder (for Commercial Burglary Use Only)
45
Figure 3-23: Remote Keyswitch Wiring
45
Figure 3-24: Remote Keypad Sounder Wiring
45
Communicators Connected to the ECP
46
Access Control Using Vistakey
47
Figure 3-25: Wiring Communicator to Keypad Terminals
47
Event Log Connections
49
Installing the 4286 VIP Module
49
Figure 3-26: Wiring the Vistakey
49
RS-232 Connectivity
51
Figure 3-27: 4286 VIP Module Connections
51
Connecting the Transformer
52
Earth Ground Connections
53
Determining the Control's Power Supply Load
53
Determining the Size of the Standby Battery
57
Figure 3-28: Connecting the Backup Batteries
58
Section 4: Downloading
59
General Information
59
Getting On-Line with a Control Panel
60
Direct-Wire Downloading
61
Telco Handoff
61
Section 5: Setting the Real-Time Clock
63
General Information
63
Setting the Time and Date
63
Section 6: User Access Codes
65
General Information
65
User Codes and Levels of Authority
65
Multiple Partition Access
66
Adding a Master, Manager, or Operator Code
67
Changing a Master, Manager, or Operator Code
68
Deleting a Master, Manager, or Operator Code
68
Exiting the User Edit Mode
68
Section 7: Testing the System
69
Battery Test
69
Dialer Test
69
Fire Drill Test (Code + [#] + 69)
69
One-Man Fire Walk-Test (Code + [#] + 68)
69
Burglary Walk-Test
70
Armed Burglary System Test
71
Testing Wireless Transmitters
71
Trouble Conditions
72
To the Installer
73
Section 8: Using the Vista-32FBPT as a Slave Communicator
75
Wiring
75
Programming
75
Figure 8-1: Slave Communicator Wiring Diagram
75
Sending Vista-32FBPT System Troubles to the Fire Alarm Panel
76
Appendix A: Regulatory Agency Statements
77
UL Installation Requirements
77
UL864/NFPA Local Fire
77
UL864/NFPA Central Station and Remote Station Fire
77
Commercial Burglary Requirements
77
UL609 Local Mercantile Premises/Local Mercantile Safe & Vault
77
UL365 Police Station Connected Burglar Alarm
78
UL365/UL609 Bank Safe and Vault Alarm System
78
UL1610 Central Station Burglary Alarm
78
ULC Installation Requirements
78
Appendix B: Summary of System Commands
81
Appendix C: Specifications
83
Appendix D: Contact ID Codes
85
Table of Contact ID Event Codes
85
Event Log Alpha Descriptors
86
Glossary
89
Index
95
Advertisement
Honeywell VISTA-32FBPT User Manual (80 pages)
Commercial Fire and Burglary Partitioned Security Systems with Scheduling
Brand:
Honeywell
| Category:
Security System
| Size: 0.48 MB
Table of Contents
Table of Contents
3
System Overview
5
General
5
A Partitioned System
5
Zones
6
Fire Protection
6
Burglary Protection
6
Carbon Monoxide Protection
7
Alarms
7
Memory of Alarm
7
Using Schedules
7
Device Timers
8
To Access Another Partition (GOTO Command)
8
Master Keypad Operation
8
Self-Help Feature
9
About the Keypads
10
General
10
The Alpha Keypad
10
Functions of the Keypad
11
Entry/Exit Delays
15
General Information
15
Security Codes and Authority Levels
16
General Information
16
Duress Code
16
Quick Arming
16
Authority Levels
17
General Rules on Authority Levels and Changes
18
To Exit User Edit Mode
18
To Add a User
19
To Change a User's Code
21
To Delete a User
22
Accessing Other Partitions
23
To Access Another Partition
23
Global Arming
23
Master Keypad Operation
24
Common Lobby Operation
26
How User Codes Affect the Common Lobby
27
Checking for Open Zones
28
Using the / READY Key
28
Displaying All Zone Descriptors
29
Using the . READY Key
29
Bypassing Protection Zones
30
Using the 6 BYPASS Key
30
Quick Bypass
30
Displaying Bypassed Zones
31
Group Bypass
31
Zones Remaining Bypassed after Disarming
32
Arming Perimeter Only
33
Using the 3 STAY Key
33
Auto-STAY Arming
34
Arming Perimeter Only
35
Using the 7 INSTANT Key
35
Arming All Protection
36
Using the 2 AWAY Key
36
Arming All Protection
37
Using the 4 MAXIMUM Key
37
Quick Exit
38
Using the # + 9 Keys
38
Disarming and Silencing Alarms
39
Using the 1 off Key
39
Memory of Alarm
39
Using the Keyswitch
40
General
40
Arming
40
Disarming
40
Chime Mode
41
Using the 9 Key
41
Viewing Alarm Company Messages
42
General Information
42
Panic Keys
43
Using Panic Keys
43
Relay Control
44
General Information
44
Executing
44
Using #70 Relay Menu Mode
45
General Information
45
Using Schedules
46
Delaying the Closing Time
46
Temporary Open/Close Schedules
46
Programming Temporary Schedules
47
Programming Device Timers
49
General Information
49
Randomize Output Device Times
51
Using #77 Instant Activation Mode
52
Event Log Procedures
55
General Information
55
To Display the Event Log
55
Testing the System (to be Conducted Weekly)
57
Using the 5 TEST Key
57
Testing Your System
57
Fire Alarm System
58
In Case of Fire Alarm
58
Silencing a Fire Alarm
58
Event Display Lock
59
Fire Drill Test (Code + # + 69)
59
Trouble Conditions
60
Typical Trouble Displays
60
Power Failure
61
Emergency Evacuation
62
Maintaining Your System
63
Taking Care of Your System
63
Replacing Batteries in Wireless Sensors
63
Silencing Low Battery Warning Tones at the Keypad
64
Routine Care
64
Quick Guide to Fire System Functions
65
Quick Guide to Burglary System Functions
66
Summary of Audible Notification
68
Index
73
Two Year Limited Warranty
75
Honeywell VISTA-32FBPT Quick Manual (6 pages)
vista turbo fire series
Brand:
Honeywell
| Category:
Security System
| Size: 0.28 MB
Table of Contents
National Fire Protection Association Recommendations on Smoke Detectors
3
Emergency Evacuation
3
In the Event of Telephone Operational Problems
4
The Limitations of this Alarm System
4
Two Year Limited Warranty
6
Advertisement
Honeywell VISTA-32FBPT Quick Manual To User Functions (2 pages)
Brand:
Honeywell
| Category:
Security System
| Size: 0.15 MB
Advertisement
Related Products
Honeywell Ademco VISTA-32FB
Honeywell VISTA - 15P Series
Honeywell Ademco VISTA-20P
Honeywell Ademco Vista-12D
Honeywell VISTA-20PS Series
Honeywell ADEMCO Vista-12 Series
Honeywell VISTA-128BPEN
Honeywell Ademco VISTA-15PCN
Honeywell Ademco Vista-48LA
Honeywell VISTA-15P
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL