Replacing the optional internal USB memory key

Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Steps
1
Locate the USB port or USB memory key on the system board.
To locate the USB port, see the
2
If installed, remove the USB memory key from the USB port.
3
Insert the replacement USB memory key into the USB port.
Next steps
1
Follow the procedure listed in
2
While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.
Optional optical drive
Removing the optional optical drive
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
3
Remove the backplane
4
Remove the air
shroud.
5
Disconnect the power and data cables from the back of the drive.
NOTE:
Ensure that you note the routing of the power and data cable on the side of the system as you remove them from
the system board and drive. Route these cables properly when you replace them to prevent them from being pinched or
crimped.
Steps
1
Press the release tab to release the optical drive.
2
Slide the optical drive out of the system.