Lennox Prodigy 2.0 Application Manual page 117

M3 unit controller
Hide thumbs Also See for Prodigy 2.0:
Table of Contents

Advertisement

Control Parameter
No
Screen Name
Parameter Short Description
Discharge Air Control Heating
210
DACH OAT RS PRP BND
Outdoor Air Temperature Reset
Discharge Air Control Heating
211
DACH RAT RS ADJ BND
Discharge Air Control heating
212
DACH RAT RS ADJ SP
Return Air Heating Reset Set
Discharge Air Control Heating
213
DACH RAT RS PRP BND
Return Air Heading Reset
Discharge Air Control Heating
214
DACH RS LIMIT
Return Air Heating Reset Limit
Exhaust Fan Stage 1 Damper
215
EXH FN STG1 DAMP SP
Exhaust Fan Stage 1 Damper
216
EXH FN STG1 DAMP DB
Exhaust Fan Stage 2 Damper
219
EXH FN STG2 DAMP SP
Exhaust Fan Stage 2 Damper
220
EXH FN STG2 DAMP DB
223
EXH FAN STGUP DELAY
Exhaust Fan Stage Up Delay
224
EXH FAN STGDWN DLAY
Exhaust Fan Stage Down Delay
Advance Airflow Low Speed
228
CL LO CFM CALIB
Advance Airflow Hi Speed
229
CL HI SPD CALIB
Advance Airflow Medium Speed
230
CL MED LO SPD CALIB
Advance Airflow Medium High
231
CL MED HI SPD CALIB
Advance Airflow Heat CFM
232
HEAT CFM CALIB
Advance Airflow Vent CFM
233
VENT CFM CALB
Advance Airflow Low Speed
234
LO SP CFM ALARM SP
Advance Airflow Low Speed
235
LO SP CFM ALARM EU
Table 64. M3 Control Parameters
Min.
1.0
Proportional Band
Return Air Temperature
0.0
Adjustment Band
50.0
Point
1.0
Proportional Band
5.0
0.0
Set Point
Check unit parameter
label as default may
0.0
Deadband
be altered at factory
0.0
Set Point
0.0
Deadband
0
0
-1200
Calibration
-1200
Calibration
-1200
Calibration
-1200
Speed Calibration
-1200
Calibration
-1200
Calibration
15.0
CFM Alarm Set Point
0
CFM Alarm Evaluation
Control Value
Default
Max.
Units
Units
20.0
60.0
°F
0.0
30.0
°F
70.0
80.0
°F
10.0
30.0
°F
10.0
20.0
°F
50.0
100.0
%
100.0
%
test.
70.0
100.0
%
10.0
100.0
%
0
300
Seconds
100
200
Seconds
0
1200
Count
0
1200
Count
0
1200
Count
0
1200
Count
0
1200
Count
0
1200
Count
25.0
100.0
%
1800
3600
Seconds
Description
Description
Discharge Air Control Heating temperature reset proportional band.
Discharge Air Control Heating return reset adjustment band.
Discharge Air Control Heating return air heating reset set point.
Discharge Air Control Heating return air heating reset proportional
band.
Discharge Air Control Heating reset limit. This limits the total DACH
reset allowed.
Exhaust fan stage 1 damper set point.
Exhaust Fan Stage 1 Damper Deadband
Exhaust Fan Stage 2 Damper Set Point
Exhaust Fan Stage 2 Damper Deadband
Exhaust Fan Stage Up Delay
Stage 1 off-delay. (Only used for 2 stage operation)
Applicable to A Box units only.
If the absolute value of this parameter is greater than Parameter 17.
then this is not considered in target calculation.
Applicable to A Box units only.
If the absolute value of this parameter is greater than Parameter 14.
then this is not considered in target calculation.
Applicable to A Box units only.
Applicable to A Box units only.
Applicable to A Box units only.
Applicable to A Box units only.
Applicable to A Box units only.
Applicable to A Box units only.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents