UNCTION
Pulse Output FB
This section describes the pulse output FB of the SmartAXIS and its functions. The pulse output FB outputs pulses from the pulse
output port according to the specified settings.
Symbol
Name and Diagram
Pulse Output
EN
PULS
INI
Pulse Width Modulation
EN
PWM
INI
Ramp Pulse Output
EN
RAMP
INI
DIR
Zero Return
EN
ZRN
INI
DE
Advanced Ramp
EN
ARMP
INI
INT
Data Logging FB
This section describes the data Logging FB of the SmartAXIS and its functions. The data Logging FB saves log data for devices to
the SD memory card.
Symbol
Name and Diagram
Data Log
EN
DLOG
Data Trace
EN
TRACE
8-14
B
R
LOCKS
EFERENCE
PULS
OUT
Outputs pulses at the specified frequency.
Outputs pulses at the specified frequency and duty
PWM
OUT
cycle.
RAMP
OUT
Outputs pulses with the frequency change function.
ZRN
OUT
Outputs pulses while the proximity signal is off.
Output pulses with the frequency change function
ARAMP
OUT
according to the settings configured in the frequency
table.
Saves the values of the specified devices in the
DLOG
OUT
specified data format as a CSV file on the SD
memory card.
Saves the values of the previous number of scans for
TRACE
OUT
the specified device in the specified data format as a
CSV file on the SD memory card.
S
AXIS P
MART
RO
Function
Function
/L
U
'
M
FT9Y-B1378
ITE
SER
S
ANUAL
Output
FBD manual
inversion
page
X
15-1
X
15-6
X
15-11
X
15-21
X
15-26
Output
FBD manual
inversion
page
16-1
16-8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents