IDEC FT1A Series User Manual page 196

Hide thumbs Also See for FT1A Series:
Table of Contents

Advertisement

7: D
A
EVICE
DDRESSES
Device
Address
M8130
Disconnect User
M8131
Communication Connection
M8132
M8133-
M8143
M8144
Timer Interrupt Status (ON: Allowed, OFF: Prohibited)
M8145-
M8147
M8150
Comparison Result 1
M8151
Comparison Result 2
M8152
Comparison Result 3
M8153
M8154
Data Register ROM Backup
M8155
M8156-
M8157
M8160
M8161
Key Input Status
M8162
M8163
M8164
M8165
M8166
M8167
M8170
High-speed Counter (Group5/I6)
M8171
M8172
M8173
M8174
M8175
High-speed Counter (Group 6/I7)
M8176
M8177
*1 Read only when FBD program is selected as the programming method.
M8000 Start Control
M8000 is used to control the operation of the CPU. The CPU stops operation when M8000 is turned off while the CPU is running.
M8000 can be turned on or off using the WindLDR Online menu. When a stop or reset input is designated, M8000 must remain on
to control the CPU operation using the stop or reset input.
M8000 maintains its status when the CPU is powered down. When the data to be maintained during power failure is broken after
the CPU has been off for a period longer than the battery backup duration, the CPU restarts operation or not as selected in
Configuration > Run/Stop Control > Run/Stop Selection at Memory Backup Error. For details on SmartAXIS Pro/Lite
start control, see "Run/Stop Selection at Memory Backup Error" on page 5-5.
M8001 1-sec Clock Reset
While M8001 is on, M8121 (1-sec clock) is turned off.
M8002 All Outputs OFF
When M8002 is turned on, all outputs and remote outputs go off until M8002 is turned off. Self-maintained circuits using outputs
also go off and are not restored when M8002 is turned off.
M8003 Carry (Cy) and Borrow (Bw) [Ladder program only]
When a carry or borrow results from executing an addition or subtraction instruction, M8003 turns on. M8003 is also used for the
bit shift and rotate instructions. For the causes of carry (CY) and borrow (BW), when ladder program is selected as the
programming language, see Chapter 4 "Instructions Reference" – "Carry and Borrow" in the "SmartAXIS Ladder Programming
Manual".
7-4
Description
Connection 1
Connection 2
Connection 3
— Reserved —
— Reserved —
— Reserved —
Write
Read
— Reserved —
ESC Key + Up Key
ESC Key + Down Key
ESC Key + Left Key
ESC Key +Right Key
— Reserved —
Comparison Output Reset
Gate Input
Reset Input
Comparison ON Status
Overflow
Comparison Output Reset
Gate Input
Reset Input
Comparison ON Status
Overflow
S
AXIS P
/L
U
MART
RO
ITE
SER
CPU
Power
Stopped
OFF
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Operating
Cleared
Operating
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
'
M
FT9Y-B1378
S
ANUAL
Read/
Ladder
FBD
Write
Read/Write
X
Read/Write
X
Read/Write
X
Read
X
Read
X
Read
X
Read
X
Read/Write
X
X
Read/Write
X
X
Read
X
X
Read
X
X
Read
X
X
Read
X
X
*
Read/Write
X
X
*
Read/Write
X
X
*
Read/Write
X
X
Read
X
X
Read
X
X
*
Read/Write
X
X
*
Read/Write
X
X
*
Read/Write
X
X
Read
X
X
Read
X
X

Hide quick links: