24 - 44
DISTRIBUTION
HVAC HOUSING (Continued)
(3) Remove the two screws that secure the HVAC
harness connector to the HVAC housing and remove
the HVAC wire harness (Fig. 9).
Fig. 9 HVAC Wire Harness Connector
1 - WIRE HARNESS CONNECTOR
2 - SCREW (2)
(4) Remove the screws that secure the blower
motor to the HVAC housing and remove the blower
motor.
(5) Remove the screws that secure the blower
motor resistor or power module (depending on appli-
cation) to the HVAC housing and remove it from the
housing.
(6) Remove the screws that secure the air inlet
housing to the HVAC housing and remove the air
inlet housing.
(7) Remove the three screws that secure the recir-
culation door actuator to the air inlet housing and
remove the actuator (Fig. 10).
(8) Remove the screw that secures the recircula-
tion door actuator gear to the air inlet housing and
remove the gear (Fig. 11).
Fig. 10 Recirculation Door Actuator
1 - HVAC AIR INLET HOUSING
2 - RECIRCULATION DOOR ACTUATOR
Fig. 11 Recirculation Door Actuator Gear
1 - DOOR GEAR
2 - ACTUATOR GEAR
3 - HVAC AIR INLET HOUSING
JR