S y m p to m :
P 0105-IN TAKE P RES S U RE S EN S OR S IGN AL VOLTAGE TOO LOW
Wh e n Mo n ito re d a n d S e t Co n d itio n :
P 0105-IN TAKE P RES S U RE S EN S OR S IGN AL VOLTAGE TOO LOW
Wh en Mon it or ed: Wit h t h e ign it ion on .
Set Con dit ion : In t a ke P r essu r e Sen sor Sign a l volt a ge is 0.2 volt or lower.
INTE RMITTE NT CONDITION
INTAKE P RE SSURE SE NSOR 5 VOLT SUP P LY CIRCUIT OP E N
INTAKE P RE SSURE SE NSOR
INTAKE P RE SSURE SE NSOR SIGNAL CIRCUIT SH ORTE D TO GROUND
INTAKE P RE SSURE SE NSOR SIGNAL AND GROUND CIRCUITS SH ORTE D TOGE TH E R
E NGINE CONTROL MODULE
INTAKE P RE SSURE SE NSOR SIGNAL CIRCUIT OP E N
TES T
1
N OTE: If D TC P 1611, P 2306 o r P 2332 is p re s e n t w ith th is D TC, d ia g n o s e
D TCs P 1611, P 2306 o r P 2332 be fo re d ia g n o s in g th is D TC.
Tu r n t h e ign it ion on .
Wit h t h e DRB, r ea d t h e In t a ke P r essu r e Sen sor volt a ge.
Is t h e volt a ge below 0.3 volt ?
Yes
No
2
Tu r n t h e ign it ion off.
Discon n ect t h e In t a ke P r essu r e Sen sor h a r n ess con n ect or.
Tu r n t h e ign it ion on .
Mea su r e t h e volt a ge bet ween gr ou n d a n d t h e In t a ke P r essu r e Sen sor 5-Volt Su pply
cir cu it a t t h e In t a ke P r essu r e Sen sor h a r n ess con n ect or.
Is t h e volt a ge a bove 4.9 volt s?
Yes
No
P OS S IB LE CAU S ES
ACTION
→ Go To 2
→ Go To 8
→ Go To 3
→ Repa ir t h e In t a ke P r essu r e Sen sor 5-Volt Su pply cir cu it for a n
open .
P er for m ROAD TE ST VE RIF ICATION - VE R-2.