Figure 116: Access Multi-Homing - Link Failure - Alcatel-Lucent 7750 SR Manual

Os services guide
Hide thumbs Also See for 7750 SR:
Table of Contents

Advertisement

CFM Message - New Opcode
Sorce: CC1 Dest: CFM-Mcast
BMAC
BEB
D
P12
BMAC
Active
C1
Bridge Table on C
ISID 100 CMAC 2 A1
ISID 100 CMAC 1 P12
On failure of the active link P11 on BEB C the following processing steps apply:
7750 SR OS Services Guide
Bridge Table on BCB E
B-MACA1
P13
B-MACC1
P15
P8
P6
BMAC
D
C
MC-LAG
P11
Standby
P11
Active
ES1
C-MAC-1
P6

Figure 116: Access Multi-Homing - Link Failure

MC-LAG protocol activates the standby link P12 on the pair BEB D.
BMAC C1 becomes active on BEB D and any traffic received on BEB C with destination
BMAC C1 is forwarded on the corresponding I-VPLS SAPs on P12.
BEB D determines the related B-VPLS instance(s) associated with all the I-VPLS SAP(s)
mapped to P12, the newly activated MC-LAG link(s)/LAG component(s).
Subsequently, BEB D floods in the related B-VPLS instance(s) an Ethernet CFM-like
message using C1 as source BMAC. A vendor CFM opcode is used followed by an
Alcatel-Lucent OUI.
As a result, all the FIB entries in BCBs or BEBs along the path will be automatically
updated to reflect the move of BMAC C1 to BEB D.
Note that in this particular configuration the entries on BEB A do not need to be updated
saving MAC Flush operation.
BCB-E
Root
P16
P13
P15
P14
P4
BMAC
BEB
BEB
B
C
B
P10
BMAC
BMAC
Standby
C1
A1
Virtual Private LAN Services
BCB-F
P2
BMAC
A
MC-LAG
P9
BMAC
Active
A1
ES2
C-MAC-2
Bridge Table on A
ISID 100 CMAC 2 P9
ISID 100 CMAC 1 C1
P2
OSSG352
Page 801
BEB
A

Advertisement

Table of Contents