Default
maximum number of attributes
Parameters
value — Specifies the number of attributes accepted on a per BVPLS basis.
attribute-table-high-wmark
Syntax
[no] attribute-table-high-wmark high-water-mark
Context
config>service>vpls>mrp
Description
This command specifies the percentage filling level of the MMRP attribute table where logs and traps
are sent.
Default
95%
Parameters
high-water-mark — 1%-100%
attribute-table-low-wmark
Syntax
[no] attribute-table-low-wmark low-water-mark
Context
config>service>vpls>mrp
Description
This command specifies the MMRP attribute table low matermark as a percentage. When the
percentage filling level of the MMRP attribute table drops below the configured value, the
corresponding trap is cleared and/or a log entry is added.
Default
90%
Parameters
low-water-mark — 1%-100%
flood-time
Syntax
flood-time flood-time
no flood-time
Context
config>service>vpls>mrp
Description
This command configures the amount of time, in seconds, after a status change in the VPLS service
during which traffic is flooded. Once that time expires, traffic will be delivered according to the
MMRP registrations that exist in the VPLS.
Default
3 seconds
Parameters
flood-time — Specifies the MRP flood time, in seconds.
7750 SR OS Services Guide
Values
SR-7/SR-12:
SR-1
Values
3 — 600
1 — 2047
1 — 1023