Siemens SIMATIC TIM 3V-IE DNP3 System Manual page 292

Industrial remote communication telecontrol
Table of Contents

Advertisement

Diagnostics and upkeep
7.3 SINAUT diagnostics and service tool
Event ID
Detailed
(hex)
event
(hex)
F560
072A
F560
072D
F560
072E
F560
0730
F560
0731
F560
0732
F560
0733
F560
0736
F560
0737
F560
073B
F560
073D
F560
073E
F560
0742
F560
0744
F560
074A
F560
074B
F560
074C
F560
0752
F560
0755
F560
0759
F560
0760
F560
0761
F560
0762
F560
0763
F560
0766
F560
0767
F560
0768
F560
076C
F560
076D
F560
076E
F560
0773
F560
0774
Diagnostic messages and activation of the group error LED
If an error occurs during startup, the read group LED (SF) of the TIM lights up and a
message to this effect is entered in the diagnostic buffer of the TIM.
If the TIM is installed as a CP in an S7-300 rack, a diagnostic interrupt is sent to the CPU.
292
Meaning
Basic channel memory assignment error.
TD7-Par: Wrong channel data type.
Unknown channel type.
TD7-Par: Invalid scan cycle ID.
Memory assignment error creating the object list for the current subscriber.
TD7-SDB: Number of objects does not match the number of objects in the header.
A read job to the CPU was not responded to after 1 ms.
TD7-Com: CPU communication error in object X, channel Y.
TD7-Com: CPU access error for object X, channel Y.
Memory assignment error creating the message buffer for a scan cycle.
A write job to the CPU was not responded to after 1 ms.
TD7-Com: Negative acknowledgment from LAN communication for job from scan cycle.
TD7-Run: Error reading an input trigger.
TD7-Par: Object without channels.
TD7-Par: Invalid address with trigger signal.
TD7-Par: Invalid address for net data in object X, channel Y.
An invalid address was reported for object X in channel Y.
TD7-SDB: Number of subscriber blocks does not match main header entry.
Unknown channel type.
Not enough memory to create the TD7onTIM send job list.
Initialization of TD7onTIM for source subscriber complete.
The general request of a subscriber is incomplete.
Timeout in the general request to a subscriber.
The general request of object X of a destination subscriber is incomplete.
Message with unknown source subscriber.
Unknown start index in received organizational message.
TD7-Run: Received organizational message not accepted due to invalid length.
Invalid start index in received data message.
TD7-Run: Received data too large for destination object.
TD7-Run: Start index of received data message does not match the receive channel of the
destination object.
TD7-Run: Object without partner or channels.
TD7-Run: No destination object found.
System Manual, 12/2015, C79000-G8976-C253-04